OWNER’S MANUAL

INSTALLATION INSTRUCTIONS FOR CONVERSION NATURAL TO PROPANE/LP

WARNING: This conversion kit shall be installed by a quali- fied service agency in accordance with the manufacturer instruc- tions and all applicable codes and requirements of the author- ity having jurisdiction. If the in- formation in these instructions is not followed exactly, a fire, ex- plosion, or production of carbon monoxide may result causing property damage, personal injury, or loss of life. The qualified ser- vice agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions sup- plied with the kit.

BEFORE YOU BEGIN

The conversion parts are packaged with the unit. Please check the contents before be- ginning this conversion.

Main Burner

Orifice

Propane/LP

Propane/LP Pilot orifice

Note: The pilot orifice has the number 30 stamped on it for identification purposes.

Figure 54 - Main Burner Orifice and Pilot Orifice

Make sure the gas control valve is in the OFF position and all electrical power to the appliance of OFF.

Wait five (5) minutes to clear out any gas. Smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the For Your Safety, Read Before Lighting, page 19.

PREPARATION

To remove louvers , pull end spring latches toward the center of the appliance simulta- neously until they are disengaged from lo- cating holes.

To open glass door, undo the latches located on the top and bottom of the firebox (see Figure 56). Carefully swing the glass door to the fully open position.

Carefully remove the log set and grate from the burner and place them outside the com- bustion chamber. Remove two screws hold- ing the burner and remove burner. Remove the two side refractories and hearth pan (see Figure 55).

Glass Door

Louvers

Grate and Logs

Burner

Hearth Pan

Refractories

Figure 55 - Remove Louvers, Logs, Burner, Hearth Pan, and Refractories

OPEN

CLOSE

INSTALLATION

Remove the main burner orifice and replace with the propane/LP conversion orifice sup- plied in the conversion kit (see Figure 57). Apply a small amount of thread sealant to the main burner orifice before tightening.

Remove the compression nut from the pilot and replace the propane/LP pilot orifice with supplied orifice from conversion kit (see Figure 57).

IMPORTANT: Be careful not to bend or kink aluminum tubing during the conver- sion. Make sure the compression sleeve and pilot orifice are properly mated and aligned before retightening the compression nut.

Main

Burner

Orifice

Pilot

Orifice

Sleeve

Compression

Nut

Figure 57 - Main Burner Orifice and Pilot Orifice

Figure 56 - Open Latch

Continued

106442

21

Page 21
Image 21
Desa MDVFST installation manual Preparation, Installation

MDVFST specifications

Desa MDVFST, an innovative platform designed for multi-dimensional visualization and feature selection, is revolutionizing data analytics in various industries. The core objective of Desa MDVFST is to simplify the process of extracting meaningful insights from complex datasets, enabling analysts and decision-makers to make informed choices swiftly and effectively.

One of the standout features of Desa MDVFST is its ability to handle multi-dimensional data with ease. It employs advanced algorithms to visualize relationships between various data points, allowing users to discern patterns that might be obscured in traditional data analysis methods. This multi-dimensional approach contributes significantly to enhanced data comprehension, leading to more accurate predictions and strategic decisions.

Desa MDVFST is built on a robust technology stack that includes machine learning and artificial intelligence. These technologies are integrated into the platform to automate feature selection, a process critical in identifying the most relevant variables that impact performance. By leveraging machine learning algorithms, Desa MDVFST minimizes human error and enhances efficiency, leading to faster project completion times without sacrificing quality.

Another remarkable characteristic of Desa MDVFST is its user-friendly interface, designed for professionals across various technical backgrounds. This democratization of data analysis ensures that stakeholders from different sectors can utilize the platform without extensive training. The interface allows users to manipulate datasets interactively, providing real-time insights and visualizations that facilitate better decision-making.

Moreover, Desa MDVFST emphasizes scalability, ensuring that businesses can adapt the platform to varying data sizes and complexities. Whether a small enterprise or a large corporation, users can tailor the platform to meet their specific needs, making it a versatile solution for a wide range of applications, from marketing analytics to financial forecasting.

In addition, Desa MDVFST incorporates cloud technology, enhancing accessibility and collaboration among team members. Users can access the platform from any location, ensuring that teams can work together seamlessly, regardless of geographical boundaries.

In conclusion, Desa MDVFST is an advanced tool set to transform the landscape of data analytics with its multi-dimensional visualization capabilities, machine learning-driven feature selection, user-friendly interface, scalability, and cloud accessibility. As businesses increasingly rely on data-driven strategies, Desa MDVFST emerges as a vital resource in achieving actionable insights and a competitive edge in the marketplace.