OWNER’S MANUAL
VENTING INSTALLATION
Continued
Horizontal Termination
Configurations
Figures 18 through 20 show different con- figurations for venting with horizontal termi- nation. Each figure includes a chart with vertical minimum/maximum and horizontal maximum dimensions which must be met. All connections must be sealed with high temperature silicone sealant (outer pipe only) as specified in the second warning statement
Vinyl
Standoff
(MDVGFK Kit Shown) |
| |
Horizontal Venting | UP | |
Vertical (V) | Horizontal (H) |
|
| ||
| ||
49.5" min. | 15" max. |
|
(45° elbow, 1' vertical pipe, 90° elbow) |
| |
61.5" min. | 34" max. |
|
73.5" min. | 58" max. |
|
85.5" min. | 10' max. |
|
102.5" min. | 20' max. |
|
45° Starter
Elbow
Note: The 30° Starter
Elbow Must Be
Discarded and
Replaced with a 45°
Starter Elbow D2060
Purchased Separately.
on page 6. All horizontal terminations re- quire 1/4" rise per 12" of horizontal run.
Figure 18 - Horizontal Termination Configuration for Rigid Venting Using One 90° Elbow
Horizontal Venting
See information in Figure 18 for Vertical(V) and Horizontal(H) maxi- mums and minimums. The same amounts apply for flexible venting.
Note: If your installation has wood or vinyl siding, you must install the wood/vinyl siding standoff D5000
UP
FGFVK Vent Kit Shown
Figure 19 - Horizontal Termination Using Flexible Venting
Venting with Two 90° Elbows
Vertical (V) | Horizontal (H1) + |
| Horizontal (H2) |
5' min. | 4' max. |
6' min. | 8' max. |
7' min. | 10' max. |
8' min. | 15' max. |
20' max. | 20' max. |
Note: If your installation has wood or vinyl siding, you must install the wood/vinyl siding standoff D5000
45° Starter Elbow
Figure 20 - Horizontal Termination Configuration for Rigid Venting Using Two 90° Elbows with Termination at 90° with Fireplace
Continued
106442 | 9 |