MDVFST
VENTING INSTALLATION
Continued
3. Attach vent pipe assembly to the fire- |
place. Set fireplace in front of it’s per- |
manent location to insure minimum |
clearances. Mark the wall for a 10" |
square hole (for noncombustible ma- |
terial such as masonry block or con- |
crete, a 7 1/2" diameter hole is accept- |
able). See Figure 14. The center of the |
4.Apply a bead of
6.Carefully move the fireplace with vent assembly attached toward the wall and insert the vent pipe into the horizontal termination. The pipe overlap should be a minimum of 1 1/4". Apply silicone to the outer pipe connection. Fasten all vent connections with screws provided. Refer to Framing on page 4 for instruc- tions on securing unit to framing or floor.
7.Slide the wall thimble against the inte- rior wall surface and attach with screws provided (see Figure 17).
hole should line up with the center- |
line of the horizontal rigid vent pipe. |
Cut a 10"x10" (254mm x 254mm) |
square hole through combustible ex- |
terior wall (7 1/2" [190mm] diameter |
hole if noncombustible). Frame as nec- |
essary (see Figure 14). |
| 4" Clamp | |
Female | 7" Clamp | |
Locking | ||
| ||
Lugs |
| |
| Spacer | |
| Spring | |
Male | 4" Flex | |
Pipe | ||
Slots | ||
|
WARNING: Do not recess vent termination in to any wall. This will cause a fire hazard.
For vinyl or stucco siding use vinyl sid- ing standoffs between vent cap and ex- terior wall. The vinyl siding standoff pre- vents excessive heat from melting the vinyl siding material. Bolt the vent cap to the standoff. Apply
5.Slide the wall thimble over the vent pipe before connecting the horizontal run to the vent cap (see Figure 17).
Nut
Apply Mastic
to All Four Sides
Cut Wood or Vinyl Siding Away to Fit Standoff
Wood Screw
Standoff
UP
Bolt
Vent Cap
7" Flex |
Pipe |
Rigid Vent Pipe Flexible Vent Pipe |
Figure 13 - Vent Pipe Connections
Vent Opening
Combustible Wall
10"
(254mm)
10"
(254mm)
(Framing
Apply Mastic to All Four Sides
UP
Wood
Screw
Vent Cap
Figure 15 - Installing Horizontal Vent Cap
Figure 16 - Installing Vinyl Siding Standoff
Interior Wall
Surface
Wall
Thimble
Vent Cap | Screw |
(Horizontal |
|
Vent Opening
Detail)
Termination) | Horizontal | |
Vent Pipe | ||
|
Noncombustible Wall
7 1/2" (190mm)
Figure 17 - Connecting Vent Cap with Horizontal Vent Pipe
Figure 14 - Vent Opening Requirements
8 | 106442 |