OWNER’S MANUAL
SELECTING
LOCATION
To determine the safest and most efficient location for your appliance, consider the following guidelines:
1.The location must allow for proper clearances (see Clearances).
2.Consider a location where heat output would not be affected by drafts, air con- ditioning ducts, windows, or doors.
3.A location that avoids the cutting of joists or roof rafters makes installation easier.
In selecting a location, the following pre- cautions must be observed:
1. A projection may be ideal for a new ad- |
dition on an existing finished wall. See |
Horizontal Termination Configuration, |
page 9, or Vertical Termination Con- |
figuration, pages 10 through 12. |
2. Do not locate appliance close to where |
gasoline or other flammable liquids may |
be stored. The appliance must be kept clear |
and free from combustible materials. |
3. Do not connect this appliance to a |
chimney system used for solid fuel |
burning fireplace. |
Figure 2 - Possible Installation of See-
Thru Fireplace
PRE-INSTALLATION PREPARATION
CLEARANCES
Minimum clearances to combustibles are: |
| |
• Back and Sides of Fireplace: | 0" min. | |
• | Vent Surfaces: | 1" (2.5cm) min. |
• Ceiling to Top of Opening: | 36" (91cm) min. | |
• | Floor: | 0" min. |
• Wall to Front of Glass: | 36" (91cm) min. | |
• Perpendicular Wall to Opening of Unit: | 2" (5cm) min. | |
• | Top Spacer: | 0" min. |
4. | Due to high temperatures, do not lo- |
| cate this appliance in high traffic areas |
| or near furniture and draperies. |
5. | This fireplace may be installed in bed- |
| rooms or bathrooms in accordance with |
| local codes. |
6. | Never obstruct the openings of the ap- |
| pliance or flow of ventilation air. Keep |
| the control compartments accessible. |
7. | Do not use this appliance if any part |
| has been under water. Immediately |
CEILING
36"
(914mm) Top Spacers
Min.
WALL
36" |
|
(914mm) |
|
Min. | 0" Floor |
CAUTION: Do not block re- quired air spaces with insula- tion or any other material. Do not obstruct the effective opening of the appliance with any type of facing material.
contact a local service technician to ex- |
amine the appliance and to replace any |
part(s) of the control ignition system |
and other related components that have |
submerged under water. |
Figure 3 - Minimum Clearances
Left Side | TOP VIEW | 0" | Drywall |
Surround |
|
| |
(0" Min.) |
|
|
|
|
|
| 2 x 4 Stud |
Combustible |
| Minimum 1" | |
Material |
| ||
|
| Clearance from | |
|
| Side | |
Right Side |
|
|
|
Surround | 2" (51mm) |
|
|
(0" Min.) | 36" |
| |
|
|
| |
Perpendicular | Wall In Front Of Glass | (914mm) | |
|
| ||
36" (91cm) Min. |
|
| |
Wall 2" (51mm) |
|
| |
|
|
| |
Min. From Opening |
|
|
|
Figure 4 - Minimum Clearances | Continued |
106442 | 3 |