SELECTING

LOCATION

To determine the safest and most efficient location for your appliance, consider the following guidelines:

1.The location must allow for proper clearances (see Clearances).

2.Consider a location where heat output would not be affected by drafts, air con- ditioning ducts, windows, or doors.

3.A location that avoids the cutting of joists or roof rafters makes installation easier.

In selecting a location, the following pre- cautions must be observed:

1. A projection may be ideal for a new ad-

dition on an existing finished wall. See

Horizontal Termination Configuration,

page 9, or Vertical Termination Con-

figuration, pages 10 through 12.

2. Do not locate appliance close to where

gasoline or other flammable liquids may

be stored. The appliance must be kept clear

and free from combustible materials.

3. Do not connect this appliance to a

chimney system used for solid fuel

burning fireplace.

Figure 2 - Possible Installation of See-

Thru Fireplace

PRE-INSTALLATION PREPARATION

CLEARANCES

Minimum clearances to combustibles are:

 

• Back and Sides of Fireplace:

0" min.

Vent Surfaces:

1" (2.5cm) min.

• Ceiling to Top of Opening:

36" (91cm) min.

Floor:

0" min.

• Wall to Front of Glass:

36" (91cm) min.

• Perpendicular Wall to Opening of Unit:

2" (5cm) min.

Top Spacer:

0" min.

4.

Due to high temperatures, do not lo-

 

cate this appliance in high traffic areas

 

or near furniture and draperies.

5.

This fireplace may be installed in bed-

 

rooms or bathrooms in accordance with

 

local codes.

6.

Never obstruct the openings of the ap-

 

pliance or flow of ventilation air. Keep

 

the control compartments accessible.

7.

Do not use this appliance if any part

 

has been under water. Immediately

CEILING

36"

(914mm) Top Spacers

Min.

WALL

36"

 

(914mm)

 

Min.

0" Floor

SELECTING CAUTION: Do not block re- quired air spaces with insula- tion or any other material. Do not obstruct the effective opening of the appliance with any type of facing material.

contact a local service technician to ex-

amine the appliance and to replace any

part(s) of the control ignition system

and other related components that have

submerged under water.

Figure 3 - Minimum Clearances

Left Side

TOP VIEW

0"

Drywall

Surround

 

 

(0" Min.)

 

 

 

 

 

 

2 x 4 Stud

Combustible

 

Minimum 1"

Material

 

 

 

Clearance from

 

 

Side

Right Side

 

 

 

Surround

2" (51mm)

 

 

(0" Min.)

36"

 

 

 

 

Perpendicular

Wall In Front Of Glass

(914mm)

 

 

36" (91cm) Min.

 

 

Wall 2" (51mm)

 

 

 

 

 

Min. From Opening

 

 

 

Figure 4 - Minimum Clearances

Continued

106442