TROUBLE- | WARNING ICONG 001WARNING |
SHOOTING | If you smell gas |
• Shut off gas supply. | |
Continued | • Do not try to light any appliance. |
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Clean- ing supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
| OBSERVED | POSSIBLE | REMEDY |
|
|
| |||
| PROBLEM | CAUSE |
|
|
| ||||
|
|
|
|
|
|
|
|
| |
| Heater produces a | 1. | Metal expanding while | 1. | This is common with |
|
|
| |
| clicking/ticking noise |
| heating or contracting |
| most heaters. If noise is | ||||
| just after burner is lit |
| while cooling |
| excessive, contact |
|
|
| |
| or shut off |
|
|
| qualified service person | ||||
|
|
|
|
|
|
|
|
| |
| Heater produces | 1. | Heater burning vapors | 1. | Ventilate room. Stop |
|
|
| |
| unwanted odors |
| from paint, hair spray, |
| using odor causing |
|
|
| |
|
|
| glues, etc. (See IMPOR- |
| products while heater is | ||||
|
|
| TANT statement above) |
| running |
|
|
| |
|
| 2. | Low fuel supply | 2. | Refill supply tank |
|
|
| |
|
| 3. | Gas leak. See Warn- | 3. | Locate and correct | all | |||
|
|
| ing statement at |
| leaks (see Checking Gas | ||||
|
|
| top of page |
| Connections, page 21) | ||||
|
|
|
|
|
|
|
|
| |
| Heater shuts off in | 1. | Not enough fresh air is | 1. | Open window and/or |
|
|
| |
| use (ODS operates) |
| available |
| door for ventilation |
|
|
| |
|
| 2. | Low line pressure | 2. | Contact local propane/ | ||||
|
|
|
|
| LP gas company |
|
|
| |
|
| 3. | ODS/pilot is partially | 3. | Clean ODS/pilot (see |
|
|
| |
|
|
| clogged |
| Cleaning and Mainte- | ||||
|
|
|
|
| nance, page 28) |
|
|
| |
|
|
|
|
|
|
|
|
| |
| Gas odor even when | 1. | Gas leak. See Warn- | 1. | Locate and correct | all | |||
| control knob is in |
| ing statement at |
| leaks (see Checking Gas | ||||
| OFF position |
| top of page |
| Connections, page 21) | ||||
|
| 2. | Control valve defective | 2. | Replace control valve | ||||
|
|
|
|
|
|
| |||
| Gas odor during | 1. | Foreign matter be- | 1. | Take apart gas tubing | ||||
| combustion |
| tween control valve |
| and remove foreign |
|
|
| |
|
|
| and burner |
| matter |
|
|
| |
|
| 2. | Gas leak. See Warn- | 2. | Locate and correct all | ||||
|
|
| ing statement at |
| leaks (see Checking |
|
|
| |
|
|
| top of page |
| Gas Connections, |
|
|
| |
|
|
|
|
| page 21) |
|
|
| |
|
|
|
|
|
|
|
|
| |
| Moisture/condensation | 1. | Not enough combus- | 1. | Refer to Air for Com- |
|
|
| |
| noticed on windows |
| tion/ventilation air. |
| bustion and Ventilation | ||||
|
|
|
|
| requirements |
|
|
|
|
|
|
|
|
| (page 8) | 31 |