CONNECTING

IMPORTANT:

Hold pressure regulator with wrench when connecting it to gas piping

 

TO GAS

and/or fittings.

 

 

 

 

 

Note: Burner bracket

SUPPLY

 

 

 

 

Pressure

 

not shown for clarity

Continued

 

Regulator

 

 

 

 

 

 

 

1/2" NPT

 

 

 

Pipe Nipple

 

 

 

 

 

Ground

Heater

 

 

 

Union

Cabinet

 

 

Tee Joint

Joint

 

 

Test

Reducer

 

Manual

 

 

Shutoff

 

Gauge

Bushing to

 

 

Connection *

1/8" NPT

 

Valve *

 

 

 

 

 

 

1/8" NPT

 

From

 

 

 

External

 

 

Plug Tap

 

 

 

 

Regulator

 

 

 

 

 

 

Tee Joint

(11" W.C. to 14" W.C. Pressure)

 

 

 

 

 

Sediment

Pipe

3" Minimum

 

 

Trap

Nipple

 

 

 

 

Cap

Figure 25 - Gas Connection

 

 

 

 

 

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 34.

CHECKING

WARNING ICONG 001WARNING

GAS

Test all gas piping and connections for leaks after installing or

CONNECTIONS

servicing. Correct all leaks at once.

 

 

 

WARNING ICONG 001WARNING

 

Never use an open flame to check for a leak. Apply a mixture of

 

liquid soap and water to all joints. Bubbles forming show a leak.

 

Correct all leaks at once.

 

 

 

WARNING ICONG 001CAUTION

 

Make sure external regulator has been installed between propane/

 

LP supply and heater. See guidelines under Connecting to Gas

 

Supply, page 20.

 

 

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG

1.Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

Continued 21

101935

Page 21
Image 21
Desa RFP28TB installation manual Connecting, To GAS, Supply, Checking GAS, Connections