Desa TB108, TB111 Plastic Foot and Leg Extensions, Cord Cleats, Handle and Foot Assembly

Models: 000 BTU TB101 TB100, TB104, TB106, TB110, TB102, TB111, TB114, TB101,TB105, TB107, TB112, TB103, TB108, TB113 000 BTU TB103 TB113 TB106 TB105 TB107 TB104 TB110 85 TB108 TB100 TB112 170 TB114 125 TB111

1 56
Download 56 pages 9.45 Kb
Page 4
Image 4
Handle

Unpacking

1.Remove all packing items applied to heater for shipment. Keep plastic cover cap (attached to heater inlet connector and hose/regulator assembly) for storage.

2.Remove all items from carton.

3.Check all items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

Assembly

IMPORTANT: Do not use this product without leg and foot assembly.

Handle

Attach handle to control box with 2 screws (long) as shown in Figure 3.

Plastic Foot and Leg Extensions

1.Insert leg extensions into outlet end cap until small hole lines up with larger hole, visible from inside of outlet end cap (see Figure 3). Fasten leg extensions with provided screws (short).

2.Insert plastic foot ends into each leg ex- tension and set heater to desired angle.

Small post screws on plastic foot will snap into holes in leg extensions.

Cord Cleats

Install cord cleats on side of end caps as shown in Figure 3 with screws provided (short).

Outlet Long screws

 

End Cap Handle

Cord

 

Cleat

Plastic Foot and Leg Extensions Short

 

Leg Extension Screw

Small

Fastening

Screw (short)

Post

 

 

Leg Extension

Cord CleatsFigure 3 - Handle and Foot Assembly Plastic Foot

Figure 3 - Handle and Foot Assembly

Theory of Operation

The Fuel System: The hose/regulator assembly attaches to the propane gas supply. For 55/85/125 models, the propane gas moves through the automatic control valve, burn rate adjustment valve and out the injector. For 170 models, the propane gas moves through the solenoid valve, burn rate adjustment valve and out the injector.

The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.

The Ignition System: For 55/85/125 models the high voltage ignitor sends voltage to the spark ignitor. For 170 models direct spark ignitor sends voltage to the spark ignitor. The spark ignitor ignites the fuel and air mixture.

The Safety Control System: This system causes the heater to shut down if the fame goes out. The motor will continue to run, but no heat is produced.

High Voltage Ignitor (55/85/125

Automatic Control Valve

 

(55/85/125 models only)

 

Models) or DSI (170 Models)

 

 

 

Solenoid Valve

 

Injector

 

 

Thermal

 

 

(170 models only)

Limit Switch

 

 

 

 

 

 

 

 

Power

Hose/

Clean

 

 

 

Regulator

 

 

 

Cord

 

 

 

Assembly

Heated

 

 

 

 

 

 

 

Cool

 

Air Out

 

 

 

 

 

 

 

Air In

 

(Front)

 

 

 

 

 

 

 

(Back)

 

 

 

 

 

 

Combustion

Spark Ignitor

Fan

 

Motor

 

 

 

 

 

Chamber

Air For

 

Air For

 

 

Combustion

 

Heating

 

 

Figure 4 - Cross Section Operational View

 

www.desatech.com119143-01A

Page 4
Image 4
Desa TB108 Plastic Foot and Leg Extensions, Cord Cleats, Handle and Foot Assembly, Cross Section Operational View