Desa TB106, TB111, TB114 125 Continued, Fan, Motor Shaft and Setscrew, Identification, All Models

Models: 000 BTU TB101 TB100, TB104, TB106, TB110, TB102, TB111, TB114, TB101,TB105, TB107, TB112, TB103, TB108, TB113 000 BTU TB103 TB113 TB106 TB105 TB107 TB104 TB110 85 TB108 TB100 TB112 170 TB114 125 TB111

1 56
Download 56 pages 9.45 Kb
Page 9
Image 9
Figure 9 - Fan, Motor Shaft and Setscrew

Service Procedures

Continued

14.Dry fan thoroughly.

15.Replace fan on motor shaft. Place set- screw on fat of shaft. See chart in Figure

10 for distance of fan hub from end of motor shaft. Tighten setscrew firmly (40-

50 inch-pounds).

16.Remove screws securing motor mount to shell.

17.Pull motor and fan from shell. Turn motor and fan around. Carefully place back in shell. Note: Fan will go into shell first.

18.Line up mounting holes in shell with holes on motor mount. Replace 4 screws through shell and motor mount.

19.Route motor wires through hole in top of shell (see Figure 7, page 8).

20.Reconnect motor wires to the same posts on terminal block as removed in step 3, page 8 (see Figure 7, page 8).

21.Replace top cover.

22.Replace fan guard.

Setscrew

Fan

Motor

Shaft

Figure 9 - Fan, Motor Shaft and Setscrew

Identification

Model

Distance A

 

55

0.19" (4.8 mm)

 

85 0.5" (12.7 mm)* or

Fan

 

0.9" (22.9 mm)*

 

125 0.5" (12.7 mm)* or

 

 

0.9" (22.9 mm)*

A

170

0.25" (6.4 mm)

Motor

* Depending

 

on Motor Shaft Motor

Hub

 

Shaft

Setscrew

Specifications

All Models

Propane/LP Gas

Gas Supply Pressure to Regulator: Max - Bottle Pressure, Min - 25 psig (172.4 kPa)

Gas Supply Pressure Regulator Out: 20 psig (137.9 kPa)

Electrical Input: 120V, 60 Hz, 1Ø, 3a

Direct Spark Ignition

Minimum Ambient Temp. Rating: 0° F (-17.8° C)

55,000 Btu/Hr Models

30 - 55,000 Btu/Hr (8.8 - 16.1 kW)

Fuel Consumption:

1.4 - 2.6 pounds/hr (0.70 - 1.28 kg/hr)

Primary Flame Control: Thermocouple operated gas valve

Heated Air Output: 300 CFM (8.49 m3/min)

85,000 Btu/Hr Models

50 - 85,000 Btu/Hr (14.6 - 25.0 kW)

Fuel Consumption:

2.3- 3.9 pounds/hr (1.04 - 1.77 kg/hr)

Primary Flame Control: Thermocouple operated gas valve

Heated Air Output: 350 CFM (9.91 m3/min)

125,000 Btu/Hr Models

75 - 125,000 Btu/Hr (21.9 - 36.6 kW)

Fuel Consumption:

3.5- 5.8 pounds/hr (1.59 - 2.63 kg/hr)

Primary Flame Control: Thermocouple operated gas valve

Heated Air Output: 350 CFM (9.91 m3/min)

170,000 Btu/Hr Models

125 - 170,000 Btu/Hr (36.6 - 49.8 kW)

Fuel Consumption:

5.8- 7.9 pounds/hr (2.63 - 3.6 kg/hr)

Primary Flame Control:

DSI Flame Rectification

Heated Air Output: 450 CFM (12.74 m3/min)

Figure 10 - Fan Cross Section

119143-01Awww.desatech.com

Page 9
Image 9
Desa TB106 Continued, Fan, Motor Shaft and Setscrew, Identification, All Models, 55,000 Btu/Hr Models, Fan Cross Section