Desa TB107, TB111, TB114 125, TB100 Operation, Storage, Maintenance, Continued, To Restart Heater

Models: 000 BTU TB101 TB100, TB104, TB106, TB110, TB102, TB111, TB114, TB101,TB105, TB107, TB112, TB103, TB108, TB113 000 BTU TB103 TB113 TB106 TB105 TB107 TB104 TB110 85 TB108 TB100 TB112 170 TB114 125 TB111

1 56
Download 56 pages 9.45 Kb
Page 7
Image 7
To Restart Heater

Operation

Continued

To Restart Heater

If safety control stops gas fow to heater, motor will continue to run.

1.Unplug heater.

2.Wait ten seconds. Plug heater in. If heater does not restart

A. Check supply valves (on propane/LP tank). Make sure they are open.

B. Check fuel level in propane/LP tank(s). If fuel level is too low, contact local propane/ LP gas company.

If heater still does not restart, contact your local service center.

Storage

StorageCAUTION:Disconnectheater from propane supply tank(s).

1.Store propane/LP tank(s) in safe manner. See chapter 5 of Standard for Storage and

Handling of Liquefied Petroleum Gases, ANSI/NFPA 58 and the Natural Gas and Propane Installation Code CSA B149.1. Follow all local codes.

2.Place plastic cover caps over brass fit- tings on inlet connector of heater and hose/regulator assembly.

3.Store in dry, clean and safe place. Do not store hose/regulator assembly inside heater combustion chamber.

4.When taking heater out of storage, always check inside of heater. Insects and small animals may place foreign objects in heater. Keep inside of heater free from combustible and foreign objects.

Maintenance

Maintenance WARNING: Never service heater while it is plugged in, connected to propane supply, operating or hot. Severe burns and electrical shock can occur.

1.Keep heater clean. Clean heater annually or as needed to remove dust and debris. If heater is dirty or dusty, clean heater with a damp cloth.

2.Inspect heater before each use. Check connections for leaks. Apply mixture of liquid soap and water to connections. Bubbles forming show a leak. Correct all leaks at once.

3.Inspect hose/regulator assembly before each use. If hose is highly worn or cut, replace.

4.Have heater inspected yearly by a quali- fied service agency.

5.Keep inside of heater free from combus- tible and foreign objects.

119143-01Awww.desatech.com

Page 7
Image 7
Desa TB107, TB111, TB114 125, TB112 170, TB100, TB108, TB110 85 Operation, Storage, Maintenance, Continued, To Restart Heater