Desa Td125, Td126, Td127, Td128 owner manual Continued, Propane Tank and Safety Chain

Models: Td125, Td126, Td127, Td128

1 48
Download 48 pages 40.26 Kb
Page 8
Image 8
Figure 14 - Propane Tank and Safety

Assembly

Continued

13.Remove tank door. Wrench tighten regu- lator and hose assembly to manifold as shown in Figure 13. Check connections for gas leaks (see Checking for Leaks).

Note: Make sure hose and regulator as- sembly attached to manifold are never bent or kinked during installation and operation of heater.

14.Place propane/LP tank on top of base. Attach regulator.

15.Install propane tank safety chain around tank and into openings on legs as shown in Figure 14.

16.Reinstall door.

Cap Support

Figure 13 - Attaching Regulator and Safety

Chain

Figure 14 - Propane Tank and Safety

Chain

Figure 13 - Attaching Regulator and

Hose Assembly

Checking for Leaks

IMPORTANT: The heater must be leak tested before any further assembly is done. Use only a noncorrosive leak detection fluid. DO NOT USE FLAME.

Turn control knob to the OFF position. Se- curely connect regulator to propane/LP gas cylinder. Open propane/LP cylinder valve. Apply a noncorrosive leak detection fluid to connections at the manifold and regulator connections. Bubbles forming show a leak.

In case of any leaks, turn off propane/LP cylinder valve, remove manifold, check and clean connection. Reconnect manifold and leak test again.

Upon completion of leak test, and when there is no sign of a leak, turn off propane/LP cylinder valve and disconnect regulator from propane/LP gas cylinder. Remove propane/LP gas cylinder and continue to next step.

www.desatech.com121117-01B

Page 8
Image 8
Desa Td125, Td126, Td127, Td128 Continued, Propane Tank and Safety Chain, Attaching Regulator and Hose Assembly