Desa (V)CB36N(E) Installing Optional Controls, Millivolt Wiring Diagram, Wiring Diagrams

Models: (V)CB36P(E) (V)CB36N(E)

1 36
Download 36 pages 4.94 Kb
Page 13
Image 13
WIRING DIAGRAMS

INSTALLING OPTIONAL CONTROLS

Continued

WIRING DIAGRAMS

NOTICE: This appliance is equipped with a vent safety shutoff switch which will shut down the appliance in case of a venting problem. Do not bypass the vent safety shutoff switch. If the appliance should shut down, have a qualified installer, service agency, or your gas supplier inspect the vent before operating.

Millivolt Wiring Diagram CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous opera- tion. Verify proper operation after servicing.

Pilot

Millivolt Wiring Diagram

Burner Manual background Thermocouple

Incoming

Main Gas

Supply

 

ON

LO

T

 

I

 

P

 

F FO

Replace factory wiring with

105° C equivalent or higher rating

External wiring use only Class 2 thermostat wire 18 Ga. Red/White

RED

 

WHITE

HIGH LIMIT

 

SWITCH

TH

NC

TP

 

TH/TP

 

DO NOT

CONNECT

TO 120V

Wall Switch/Remote Receiver

Figure 20 - Millivolt Ignition Wiring Diagram

ELECTRONIC IGNITION Ignitor Manual background High Limit WIRING DIAGRAM

Switch

NC

 

 

 

Orange

Gas Valve

 

Red

 

 

 

 

EV1

 

MV PV THP/MVGND

 

 

Black

IgnitionControl Module

 

Black

 

Black

 

 

EV2

 

TR

High Voltage

 

 

 

 

 

 

 

Blue

 

 

Green

 

Ignition Module

Manual background Pilot Burner

Red

 

Transformer

24 VAC

White

 

 

Ground

Blue

 

120 VAC

Figure 21 - Electronic Ignition Wiring Diagram

117437-01B

www.desatech.com

13

Page 13
Image 13
Desa (V)CB36N(E), (V)CB36P(E) operation manual Installing Optional Controls, Millivolt Wiring Diagram, Wiring Diagrams