Product Features
These are a few facts that can help you understand and enjoy your vented decorative fireplace:
•The (V)CB36N(E) and (V)CB36P(E) series of vented decorative fireplaces may be recessed into an exterior chase, an interior flush wall enclosure or a
•Models (V)CB36N and (V)CB36P are equipped with a millivolt gas control system that does not require electricity to operate. A piezo ignitor is provided to light the pilot without using matches or lighters.
•Models (V)CB36N(E) and (V)CB36P(E) are equipped with an electronic ignition system that requires 120 VAC to operate. An electrode ignitor automatically lights the pilot flame when the fireplace is turned on.
•These fireplaces can accept any approved 4"
•These vented fireplaces require indoor air for combustion and must be installed in a room of sufficient size to provide adequate fresh air for safe and proper operation. The room intended for installation must be of sufficient size to meet the requirements for an unconfined space as defined in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation. If sufficient air for combustion is not available a makeup air kit model AK4 may be required to provide outside air to this appliance. Check your local codes as to specific requirements for make up air.
•This fireplace may be installed in any room of the house provided all local codes and these installation instructions are followed.
When deciding the location of your fireplace, follow these rules:
•Do not connect this fireplace to a chimney flue servicing a separate solid fuel burning fireplace or appliance.
•Do to high temperatures, do not locate this fireplace in high traffic areas, windy or drafty areas, or near furniture or draperies.
•Proper clearances must be maintained.
•If your fireplace is to be installed directly on carpeting, vinyl, tile or any combustible mate- rial other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace (see Figure 3).
•Only trim kits supplied by DESA shall be used in the installation of this fireplace, see Acces- sories, page 34.
•Do not install aftermarket vent dampers.
Manual or automatic vent dampers are not ap- proved for use with this appliance.
•Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior sur- face on the back, sides or top of your fireplace, except when clearances are required from flue vent pipe, see Clearances on page 6.
•If recessed into a wall, you can avoid extra framing by positioning your fireplace against an already existing framing member.
Flush with a wall | Corner |
Through exterior wall | Installation |
enclosed in a chase |
|
Pre-Installation
Preparation
Location and space requirements
Determine the safest and most efficient location for your DESA
Figure 2 - Common Fireplace Locations
25"
(63.5 cm)
36"
(91.4 cm)
36"
(91.4 cm)