Cleaning and
Maintenance
Continued
LOGS
•If you remove logs for cleaning, refer to In- stalling Logs and Glowing Embers, page 18, to properly replace logs.
•Use a vacuum cleaner to remove any carbon buildup on logs.
•Replace log(s) if broken. See Replacement Parts, page 34.
•Replace ember material periodically as needed. See Replacement Parts, page 34.
VENTING SYSTEM
Conduct annual inspection of the venting system following these guidelines:
1.Check areas of venting system that are ex- posed to the weather corrosion (rust spots or streaks and in extreme cases, holes). Have these items replaced immediately by a quali- fied service person.
2.Remove the vent cap and shine a flashlight into vent. Remove any foreign material.
3.Check for evidence of excessive condensation. Continuous condensation can cause corrosion of caps, pipes and fittings and can be caused by having excessive lateral runs, too many elbows or exterior portions of the system being exposed to cold weather.
4.Inspect joints to verify that no pipe section or fitting has been distributed and loosened. Check mechanical supports such as wall straps for rigidity.
Specifications
(V)CB36N | (V)CB36NE |
• Maximum Input Rating: 18,000 Btu/hr | • Maximum Input Rating: 18,000 Btu/hr |
• Gas Type: Natural | • Gas Type: Natural |
• Orifice Size (Main Burner): #45 DMS (0.082") | • Orifice Size (Main Burner): #45 DMS (0.082") |
• Ignition: Millivolt | • Ignition: Electronic |
• Manifold Pressure: 3.5" w.c. (0.87 kPa) | • Manifold Pressure: 3.5" w.c. (0.87 kPa) |
• Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa) | • Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa) |
(V)CB36P | (V)CB36PE |
• Maximum Input Rating: 18,000 Btu/hr | • Maximum Input Rating: 18,000 Btu/hr |
• Gas Type: Propane/LP | • Gas Type: Propane/LP |
• Orifice Size (Main Burner): #55 DMS (0.052") | • Orifice Size (Main Burner): #55 DMS (0.052") |
• Ignition: Millivolt | • Ignition: Electronic |
• Manifold Pressure: 10" w.c. (2.5 kPa) | • Manifold Pressure: 10" w.c. (2.5 kPa) |
• Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa) | • Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa) |
All Models
•Fireplace Dimension HxWxD (Actual size of firebox measurements do not include nailing flanges or standoffs): 35.75" x 36.25" x 14.75" (90.8 x 92.1 x 37.5 cm)
•Carton Dimension HxWxD: 36.75" x 38" x 16.25" (93.3 x 96.5 x 41.3 cm)
24 | www.desatech.com |