Desa VI33PRB, VI33NRB installation manual Air For Combustion And Ventilation, Installation

Models: VI33NRB VI33PRB

1 36
Download 36 pages 24.18 Kb
Page 8
Image 8
INSTALLATION

AIR FOR COMBUSTION

AND VENTILATION

Continued

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining un- confined space. When ventilating to an adjoining unconfined space, you must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 3). You can also remove door into adjoining room (see option 3, Figure 3). Follow the National Fuel Gas Code ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

 

Outlet

Ventilated

 

Attic

 

Air

 

 

Outlet

 

 

Air

 

To Attic

 

 

 

 

To

 

 

Crawl

Inlet

 

Space

 

 

Air

 

 

 

Inlet Air

Ventilated

 

Crawl Space

 

 

Figure 4 - Ventilation Air from Outdoors

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not

Ventilation

Grills

Into Adjoining

12"

Ventilation Grills Into Adjoining Room,

install this heater as your pri- mary heat source. If you have a

Room,

Or

Option 2

central heating system, you may

Option 1

Remove

Door into Adjoining Room, Option Manual background 3

12"

Figure 3 - Ventilation Air from Inside

Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent open- ings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-con- trolled power vent. Heated air entering the attic will activate the power vent. Any outside air ducts and/or ash dumps in the fireplace shall be perma- nently closed at the time of appliance installation.

run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

Manual background WARNING: A qualified ser- vicepersonmustinstallfireplace insert. Follow all local codes.

Manual background WARNING: Make sure the selector switch is in the OFF position before installing heater

Manual background WARNING: Never install the fireplace insert

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the fireplace insert

in high traffic areas

in windy or drafty areas

8

www.desatech.com

113195-01A

Page 8
Image 8
Desa VI33PRB, VI33NRB installation manual Air For Combustion And Ventilation, Installation