Venting Installation

instructions

Continued

6.Continue to add pipe sections until the height of the vent cap meets the minimum building code requirements described in Figure 7 on page 7. Note: You must increase vent height for steep roof pitches. Nearby trees, adjoining rooflines, steep pitched roofs and other similar factors may cause poor draft or down-drafting in high winds. Increasing the vent height may solve this problem.

7.Twist-lock the vent cap onto the last section of vent pipe.

Note: If the vent pipe passes through any occupied areas above the first floor, including storage spaces and closets, you must enclose pipe. You may frame and sheetrock the enclosure with standard construction material. Make sure and meet the minimum allowable clearances to combustibles. Do not fill any of the required air spaces with insulation.

Vertical Termination Configurations Figures 21 through 24 show four different con- figurations for vertical termination.

Venting with Two 90° Elbows

 

Horizontal (H1) +

Vertical (V) Horizontal (H2)

5' min.

2' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

20' max.

8' max.

45° Elbow

Venting with One 90° Elbow

Vertical (V) Horizontal (H)

5' min.

2' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

20' max.

8' max.

45° Elbow

 

Note: Install restrictor into inner collar of fireplace as shown.

Figure 22 - Vertical Venting Configuration

Using One 90° Elbow (Vertical Round

High Wind Termination Shown)

Note: Install restrictor into inner collar of fireplace as shown.

45° Elbow

Note: Install restrictor into inner collar of fireplace as shown.

Figure 21 - Vertical Venting

Configuration Using Two 90° Elbows

with Two Horizontal Runs (Vertical

Round High Wind Termination Shown)

Venting with Two 90° Elbows

Vertical (V1)

Horizontal (H)

5' min.

6' max.

6' min.

12' max.

7' min.

18' max.

8' min.

20' max.

Note: Vertical (V1) + Vertical (V2) = 40' max.

Figure 23 - Vertical Venting Configuration

Using Two 90° Elbows (Vertical Round

High Wind Termination Shown)

116647-01B

www.desatech.com

15

Page 15
Image 15
Desa (V)T32EP-A SERIES, (V)T32EN-A SERIES Min Max 20 max Elbow, Venting with One 90 Elbow Vertical V Horizontal H