Desa (V)T32EP-A SERIES, (V)T32EN-A SERIES Pilot and burners, Logs, Venting system

Models: (V)T32EP-A SERIES, (V)T32EN-A SERIES

1 40
Download 40 pages 53.26 Kb
Page 29
Image 29

Cleaning and

Maintenance

Continued

WARNING: Only parts sup- pliedbythemanufacturershould be used when replacing broken or damaged glass door panel (see Replacement Parts, page 32). This glass door panel is a complete unit. No substitute materials may be used.

CAUTION: Wear gloves and safety glasses while handling or removingbrokenglass.Donotre- moveifglassishot.Keepchildren and pets away from glass.

If glass has been broken, carefully remove glass door (see Removing/Replacing Glass Door, page 22). Vacuum all glass pieces with a shop vac.

CAUTION: Do not vacuum if pieces are hot.

Use only the tempered glass door replacement intended for this fireplace (see Replacement Parts, page 32 for detail on ordering). No substitutions may be made. See Removing/Replacing Glass Door, page 22 for instructions for replacing glass door.

WARNING: Do not operate fireplace with the glass door unlatched, removed, cracked or broken.

pilot and burners

Remove ember material before cleaning burners and replace when cleaning is complete.

Burner and controls should be cleaned with compressed air to remove dust, dirt or lint.

Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt or lint.

logs

If you remove logs for cleaning, refer to Install- ing Logs, Lava Rock and Glowing Embers, page 24, to properly replace logs.

Use a vacuum cleaner to remove any carbon buildup on logs.

Replace log(s) if broken. See Replacement Parts on page 32.

Replace ember material periodically as needed. See Replacement Parts on page 32.

venting system

Conduct annual inspection of the venting system following these guidelines:

1.Check areas of venting system that are exposed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced immediately by a qualified service person.

2.Remove the vent cap and shine a flashlight into the vent. Remove any foreign material.

3.Check for evidence of excessive condensation. Continuous condensation can cause corrosion of caps, pipes and fittings and can be caused by having excessive lateral runs, too many elbows or exterior portions of the system being exposed to cold weather.

4.Inspect joints to verify that no pipe section or fitting has been disturbed and loosened. Check mechanical supports such as wall straps for rigidity.

116647-01B

www.desatech.com

29

Page 29
Image 29
Desa (V)T32EP-A SERIES, (V)T32EN-A SERIES installation manual Pilot and burners, Logs, Venting system