2. USING WEB-BASED MANAGEMENT
Setting Up Web Management
Before running
•IP Address
•Administrator password
•HTTP Server Enable
In addition, several other parameters may need to be configured or known to properly communicate with the switch or allow full management capability. These include:
•Default Gateway
•Trap Destination and Community Name
Configuration of these items may be made from the console user interface, which is accessible via either the serial console or Telnet. Refer to the DNswitch 800 User’s Guide that came with your system for more information about setting up either of these connections to the switch. The following subsections describe the required configuration.
Setting an IP Address
The IP address for the switch must be set before it can be managed with Digital Networks WebView. The switch IP address may be automatically set using the BootP protocol, in which case the actual address assigned to the switch must be known. Refer to the DNswitch 800 Management Guide.
The IP address may alternatively be set manually as follows:
1.Starting at the Main Menu of the console user interface, select Management Setup Menu / Network Configuration / IP Configuration.
2.Select IP Address from the menu and enter the IP address.
3.Select Subnet Mask from the menu and enter the appropriate mask.
4.Press <APPLY>.
DNswitch 800 | Using |