STOVE FEEDS PELLETS, BUT WILL NOT IGNITE AND

STOVE FEEDS PELLETS, BUT WILL NOT IGNITE AND

SHOWS WARNING CODE “L”

Possible Causes:

Possible Remedies:

 

 

 

 

 

 

 

1. Air damper open too far for ignition.

Adjust the air supply to the minimum setting for startup. In some situations, it may

 

 

be necessary to have the damper completely closed for ignition to take place. Once

 

 

there is a flame, the damper can be adjusted to the desired feed setting.

 

 

 

 

 

 

 

2. Blockage in igniter tube or inlet for igniter tube.

Remove the burn pot and clean it thoroughly. Make sure that all openings are clear.

 

 

Find the place where the igniter tube comes out of the burn pot housing. It is a small

 

 

tube located on the back of the burn pot housing. Make sure it is clear. Make sure

 

 

there is no debris around the igniter element or inside the igniter tube.

 

 

 

 

 

 

 

3. Defective igniter element.

Supply power directly to the igniter element. Watch the tip of the igniter from the

 

 

front of the stove. After about 2 minutes, the tip should glow. If it does not, the

 

 

element is defective and must be replaced. You may need a technician to perform

 

 

this test.

 

 

 

 

 

 

 

4. The thermistor heat sensor has malfunctioned.

The thermistor is a heat sensor attached to the exhaust housing. Its function is to

 

 

tell the control board that the unit has ignited properly by measuring the temperature

 

 

in the exhaust. The stove will not feed pellets at the desired heat setting until it

 

 

has received a signal from the thermistor heat sensor. If the thermistor heat sensor

 

 

is bad, the unit will go out and stop after the ignition cycle. If this situation occurs,

 

 

call your dealer or technician.

 

 

 

 

 

 

 

5. The control board is not sending power to the igniter.

Check the voltage going to the igniter during ignition. It should be a full current. If

 

 

the voltage is lower than full current, check the wiring. If the wiring is functional and

 

 

properly connected, the board is defective. You will need a technician to perform

 

 

this test.

 

 

 

 

 

 

 

6. The burn pot gaskets are missing or have to be replaced

Burn pot gaskets are located in the metal ring at the bottom of the burn pot. These

 

 

gaskets prevent heat lost from the igniters to get a fastest ignition.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STOVE FEEDS PELLETS, BUT WILL NOT IGNITE

 

 

 

 

 

 

 

 

 

 

 

 

AND SHOWS WARNING CODE “I”

 

 

 

 

 

 

Possible Causes:

 

 

Possible Remedies:

 

 

 

 

 

 

1. The igniter fuse on the control board has blown.

 

 

Remove the control board and check at the back to see if the F3 fuse is good,; if

 

 

 

 

not replace it with a 5 Amp 250V fuse. Plug the stove back and try to run the

 

 

 

 

unit.

 

 

 

 

 

 

 

 

 

 

 

 

STOVE STOPS FEEDING PELLETS AND SHOWS

 

 

 

 

 

 

 

 

 

 

WARNING CODE “O”

 

 

 

 

 

Possible Causes:

 

 

 

 

Possible Remedies:

 

 

 

 

 

 

1. The L-250 manual reset high temperature switch has tripped.

 

 

 

 

Using the owner’s manual, locate the L-250 high temperature switch.

 

 

 

 

 

 

There is a red button on it. Press the red button. If you hear a click, the

 

 

 

 

 

 

high limit had tripped. Reset the stove. The stove should now function

 

 

 

 

 

 

normally. YOU NEED TO INSPECT YOUR UNIT AT THIS POINT. The F-

 

 

 

 

 

 

250 high temperature switch will trip if the unit overheats. There might be

 

 

 

 

 

 

a problem with another component or the installation, causing the stove to

 

 

 

 

 

 

overheat. Make sure that the convection blowers work. If one of the

 

 

 

 

 

 

convection blowers has failed, this can cause the unit to overheat. Clean

 

 

 

 

 

 

any dust off of the windings and blades of the convection blower. Call

 

 

 

 

 

 

your dealer or a technician if you get this code again.

 

 

 

 

 

 

 