STOVE INSTALLATION
ECO-35 FREESTANDING PELLET STOVE
Width: 22 1/4”
Height: 28 1/2”
Depth: 25 3/16”
Weight: 190 lbs.
Flue size: 3” or 4”
Hopper Capacity: Up to 35 lbs.
(This can vary slightly depending on pellet size, length, and diameter) EPA status: exempt
Burn rate: 1.3 lbs to 4.1 lbs per hour
BTU range: 8,200 to 35000
Electrical consumption: 3.5 Amps lighting cycle
2.5Amps. continuous duty
Control board fuses: Main:
Igniter:
Electrical requirement: 120VAC 15A
Approved installations: mobile home, conventional
PREPARATION
Factory packaging must be removed, and some minor assembly work is required prior to installation :
•The black knobs must be attached to heat exchanger rods
•The coil handle must be attached to handle rod
CLEARANCES
The
FLOOR PROTECTION: minimum 6” in the front and 6” on each side. The stove must be placed on a continuous (grouted joints)
Clearances are measured from the sides, back and face (door opening) or stove body (refer to fig. 3).
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN THE INSTALLATION OF THIS UNIT.
INSTALL VENT WITH CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
This heating unit must serve as a supplementary heat source. An alternative heat source should be available in the home if needed. The manufacturer cannot be responsible for additional heating costs associated with the use of an alternative heat source.
It is highly recommended that the user buys this product from a retailer who can provide installation and maintenance advices.
BACK WALL
3"
| 2" * | |
WALL | 6" | |
SIDE | ||
|
Figure 1
Back wall installation
ADJACENT WALL
2" | 3" |
| |
| 3" |
| ADJACENTWALL |
| 2" |
Figure 2
Corner installation
6" | 6" |
| 6" |
Figure 3
Floor protection
6