STOVE STOPS FEEDING PELLETS AND SHOWS

WARNING CODE “H”

Possible Causes:

 

 

 

 

Possible Remedies:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

One of the two L-250 automatic high temperature switch has

 

The L-250 automatic high temperature switches are located on

 

tripped.

 

 

 

 

the top and bottom of the auger housing They send a signal to the

 

 

 

 

 

 

control board if the auger housing overheats. Wait until the

 

 

 

 

 

 

stove cools down AND THEN INSPECT YOUR UNIT.

 

 

 

 

 

 

Improper installation, poor maintenance, or a defective or

 

 

 

 

 

 

missing component may be causing the stove to overheat. Reset

 

 

 

 

 

 

the stove and restart it. Call a technician if you get this code

 

 

 

 

 

 

again.

 

 

 

 

 

 

 

 

*See procedure below to restart the stove.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CODE

BEFORE RESETING

 

 

TO RESET

 

 

 

H1, H2, H3

Heat exchanger and/or exhaust system

 

 

 

 

 

 

 

 

OR H4

is/are clogged. Refer to the owner’s manual

 

 

Press simultaneously for 2 seconds the reset

 

and

 

 

 

for maintenance procedures.

 

 

 

icons .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*** After 3 attempts, reset is no longer possible. Call SBI technical support.

 

 

 

 

 

 

 

 

 

 

 

 

 

STOVE STOPS FEEDING PELLETS AND SHOWS

 

 

 

 

 

 

 

 

 

 

WARNING CODE “d”

 

 

 

 

 

 

 

 

 

 

Possible Causes:

 

 

 

 

Possible Remedies:

 

 

 

 

 

1. The hopper lid has stayed open for more than 3 minutes

 

As a security measure, the auger will stop turning and feeding pellets as

 

 

 

 

 

 

soon as the hopper lid opens. It will resume normal operation as soon as

 

 

 

 

 

 

the hopper lid is closed. However, if the hopper lid stays open for more

 

 

 

 

 

 

than 3 minutes, the unit will stop and a code “d” will appear on the control

 

 

 

 

 

 

board. Close the hopper lid. Reset the unit and start it again.

 

 

 

 

 

 

 

 

 

 

 

SMOKE SMELL COMING BACK INTO THE HOME

 

 

 

 

 

 

 

Possible Causes:

 

 

 

 

Possible Remedies:

 

 

 

 

 

 

1.

There is a leak in the vent pipe system.

 

Inspect all vent pipe connections. Make sure they are sealed with RTV

 

 

 

 

 

 

silicone that has a temperature rating on 500oF or higher. Also, seal joints

 

 

 

 

 

 

with UL-181-AP foil tape.

 

 

 

 

 

 

 

 

 

 

 

 

2.

The gasket on the combustion/exhaust blower housing has

 

Inspect the gasket on the combustion/exhaust blower housing to make

 

gone bad.

 

 

 

 

 

 

 

 

 

sure it is in good shape and replace if necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUGER MOTOR STOPS FEEDING PELLETS AND COMES BACK ON

Possible Causes:

1.The auger motor is overheating and tripping the internal temperature shutoff (thermal protector).

Possible Remedies:

Start by emptying the hopper. Follow procedure described in warning code “E” section #6.