Maintenance

Cleaning and replacing the air filter

The air filter has two kinds of filters inside. Please check and clean the air filter periodically. When the indicators or a message prompts you to clean the air filter, comply with it as soon as possible. If the filters are damaged or heavily soiled, replace them with the new ones. To prepare the new filters, make contact with your dealer and tell the following type number.

Type number : UX35971 (Filter unit)

When you replace the lamp, please replace the air filter. An air filter of specified type will come together with a replacement lamp for this projector.

1.

Turn the projector off, and unplug the power cord.

2.

Allow the projector to sufficiently cool down.

 

2.

Use a vacuum cleaner on and around the filter cover.

 

3.

Pick and pull up the filter cover knobs to take it off.

3. Filter cover

4.

Use a vacuum cleaner for the filter vent of the projector.

 

5.

Take the fine meshed filter out while holding the filter

Filter cover knobs

cover. It is recommended to leave the coarse meshed

6.

filter in the filter cover as it is.

4.

Use a vacuum cleaner on both sides of the fine

 

meshed filter while holding it so it will not be sucked

 

 

in. Use a vacuum cleaner for the inside of the filter

 

 

cover to clean up the coarse meshed filter. If the filters

Intake vent

 

are damaged or heavily soiled, replace them with new

Filter unit

7.

ones.

Filter cover

Put the fine meshed filter on the coarse meshed one, turning

7.

its stitched side up.

8.

Put the filter unit back into the projector.

 

9.

Turn the projector on and reset the filter time using the FILTER

 

TIME item in the EASY MENU.

Filter

(1) Press the MENU button to display a menu.

(coarse meshed)

(2) Point at the FILTER TIME using the ▲/▼ cursor buttons,

Filter (fine meshed)

 

then press the ► cursor (or the ENTER / the RESET) button.

Stitched

 

A dialog will appear.

 

side

(3) Press the ► cursor button to select the “OK” on the dialog.

 

 

It performs resetting the filter time.

 

WARNING ►Before taking care of the air filter, make sure the power cable is not plugged in, then allow the projector to cool sufficiently.

►Use only the air filter of the specified type. Do not use the projector without the air filter or the filter cover. It could result in a fire or malfunction to the projector. ►Clean the air filter periodically. If the air filter becomes clogged by dust or the like, internal temperatures rise and could cause a fire, a burn or malfunction to the projector.

NOTE • Please reset the filter time only when you have cleaned or replaced the air filter, for a suitable indication about the air filter.

The projector may display the message such as the “CHECK THE AIR FLOW” or turn off the projector, to prevent the internal heat level rising.