Dukane CAE-20W instruction manual Operating Controls, Student Microphone

Models: CAE-20W

1 63
Download 63 pages 52.96 Kb
Page 22
Image 22
STUDENT MICROPHONE

Operating Controls

STUDENT MICROPHONE

(1A) Momentary power switch– Push to Talk.

(1B) Continuous power switch– Slide up to lock on and then talk.

(2)Power indicator –lights "green" when the power is turned either momentary or continuous.

(3)Microphone (audio pickup) - speak into this

part of the microphone.

(4)Infrared signal emitters — the infrared signal is broadcast from multiple infrared signal emitters.

(5)Battery case— Slide the battery cover down to remove.

(6)Charging terminal—charging input for charging the batteries with the AC Adapter or the battery charger

(7)Charging indicator—The charging indicator pro- vides a "red" light to indicate the following con- ditions when the power switch is off and the mi- crophone is being charged.

￿Charging: Solid steady ON

￿Finished Charging: OFF

￿Charging error (trying to charge an alka- line battery : Flashing very fast

(8)External Auxiliary input terminal (on the side) - Used to connect a CD or MP3 player or other device. Allows the user to wirelessly connect a source to the system.

(9)Single “AA” NiMH rechargeable battery or non- rechargeable Alkaline battery.

(10)Channel assignment switch. Channel switch (inside the battery case) - Set the channel of the infra- red wireless microphone to the desired channel.

Channels 1 or 2 for use with Achiever,

Ultimate II, Innovator. Channels 1 through 4 for use with Innovator..

3

 

7

4

2

8

1A

1B

5

 

 

10

 

9

6

To change the battery:

1.Slide the rear cover(5) down towards the bottom of the microphone.

2.Replace battery with a standard “AA” NiMH rechargeable.

Note: A standard “AA” Alkaline cell can be used on a temporary basis.

●Uses two Panasonic NIMH AA rechargeable batter-