Installing the Bracket
●The Infrared Receiver
Install the Infrared Receiver
1. Fix the main unit to the bracket.
Use 2 screws to fix the bracket to the side of main unit.
The torque for the screws is 1.18 N・m±0.2 N・m (12 kgf・cm±2 kgf・cm)
2.Fix the adjustment bolts.
The torque for the screws is 1.18 N・m±0.2 N・m (12 kgf・cm±2 kgf・cm)
3.After installation, make sure nothing is loose.
Do a visual check and make sure that nothing is unsteady and the screws are tight.
MTBR-07S (BT77)
Bracket
To the wall
Wire lope
4. Fix the wire lope to the wall.
Warning for the Installation the Bracket
Fix the bracket and the wire lope to the wall.
Please secure enough strength for the installed wall.
Wire Lope Requirement
Diameter : more thanφ1/16 inches
Material : High carbon steel wire rods
Caution: Please confirm to the wall there is enough strength to support the Infrared Receiver with the bracket. 106KG is five times weight about the sensor necessary above. Please do not in- stall it in plasterboard. Please reinforce it when strength is insufficient.
Please secure the AC adapter as follows when it is required to be installed higher than 30 inch from floor.
*Use metal