Dukane CAE-20W instruction manual Operating Controls, Innovator, Rear View

Models: CAE-20W

1 63
Download 63 pages 52.96 Kb
Page 19
Image 19
Manual background

Operating Controls

INNOVATOR

 

 

Rear View

13

17

B

12

11

15

16

10

18

14

9

A

9) DC power terminal

The AC adapter provided supplies 24 V DC power.

(10) Sensor input terminal

Connection via F-connector and coaxial cable for the infrared wireless sensors. It also supplies power to the sensors (24 V).

(11) Input terminal TV/DVD, CD, COMPUTER, MP3

Connections for TV/DVD, CD, COMPUTER, and MP3. (12) Line output terminal

Provides a line level output for connection of personal FM system, recording de- vices, or video conferencing systems. All input signals, including microphones an auxil- iary inputs are mixed and provided at the line output terminal.

(13) AUX mute setting switch OFF/LOW/HIGH

The Aux mute switch allows selection of whether or not the teachers voice mutes the auxiliary inputs when he or she speaks. The ‘off’ setting provides for no muting. The Low setting provides for a standard level of attenuation. The High setting provides for a faster attenuation. Set the switch to ‘low’ for normal operation.

(14) Speaker output terminal

Connections for the speakers (8 Ohms). (15) PA input terminal

When public announcements are input into the system they are played through the speakers. The user can also select to reduce the auxiliary input levels during PA an- nouncements by switching the EMG input Terminal (17).

(16) PA input volume

Adjusts the level of the PA system being played through the speakers (18) Serial transmission terminal (RS-232)

Provides for remote control of system from a computer

(A)Ground screw SIGNAL GND

(B)Mount for cable clamp - Used to bundle cables and speaker wires with tie-wraps.