◎Part 1 [Good example]

Installation Coaxial Cables

Infrared sensor connector

 

Coaxial cable :B

 

AE-DCF

Coaxial cable C

 

 

INNOVATOR

 

Coaxial cable :D

 

 

 

Coaxial cable : A

 

 

 

Coaxial cable:

Part 1 [Good example]

Coaxial cable length: If A = 120’, B = 24’, C = 12’, D = 18’, E = 30’ Results

Coaxial cable: B to E are less than 36’, and the cable length of "A: 120’ + E: 30’ = 150‘ “, therefore, there is no problem with a cable lengths. ( It is within a range of 300’. )

Part 2 [Good example]

Coaxial cable length: If A = 180’, B = 90’ , C = 105’, D = 75’, E = 99’ Results

Coaxial cable: the length of cables B to E: “ (maximum:105’ ) – (minimum:75’) = 30’ ”,therefore,

there is no problem with a cable length. ( It is within a range of 36’. )

The cable length of "A: 180’ + C: 105’ = 285‘ “, therefore, there is no problem with a cable

length. ( It is within a range of 300’. )

Part 3 [Bad example]

Coaxial cable length: If A = 150’, B = 120’, C = 135’, D = 150’, E = 165’ Results

Coaxial cable: the length of cables B to E: “ (maximum:165’ ) –(minimum:120’) =30’ ”,

therefore, there is a problem with a cable length. ( It is over the range of 36’.) The cable length of "A: 150’ +E: 165’ = 315‘; therefore, there is a problem with a

cable length. (It is over the range of 300’).