![Setting the EMG Aux Mute](/images/new-backgrounds/14488/1448891x1.webp)
Setting the EMG Aux Mute
●Setting the Emergency Mute Function
The Emergency Mute Function (EMG) (17) allows selection of whether or not the audio level of the auxiliary inputs (11) is muted when a page is received from the PA system.
11 17
(11) Input terminal
(17)EMG input terminal
To activate the mute function, use a terminal | Jumper | 17 | |
jumper to connect the "+24 V BIAS“ terminal | |||
|
(17)and the "EMG CNT“ terminal. With the jumper in place, the auxiliary inputs will be muted when a page is received. To deactivate
the muting function, connect the EMG termi- nal to the "EMG GND" terminal as shown in the diagram at right.
【notes】
The AUX mute for the PA input terminal operates independently from the teacher voice mute settings.
(Continue to next page)