C O N FIGURING THE DRM 4000

Legend to the table on the DRM 4000 FACTORY CONFIGURATION leaflet:

BASIC CONFIGURATION:

The BASIC CONFIGURATION is active when no CONTROL

 

 

INPUT is connected to ground. The BASIC CONFIGURATION

 

 

always has the lowest priority.

CONTACT 1-8:

 

The DRM 4000’s active configuration accords to the CONTROL

 

 

INPUT, which is connected to ground, as long as no other

 

 

CONTROL INPUT with a higher priority setting is connected

 

 

to ground.

PRIORITY:

 

Each CONTROL INPUT has an assigned PRIORITY between

 

 

1 and 8. PRIORITY 0 - the lowest priority level - relates to the

 

 

BASIC CONFIGURATION. The CONTROL INPUT with the

 

 

highest priority setting is the active one (PRIORITY 8 represents

 

 

the highest priority level) when several CONTROL INPUTS

 

 

are connected to ground.

Routing:

Off

The input signal is not assigned to any output.

 

Mono A

The input signal is only assigned to output A. AUX-inputs are

 

 

summed for monaural output.

 

Mono B

The input signal is only assigned to output B. AUX-inputs are

 

 

summed for monaural output.

 

Dual

The input signal is assigned to the outputs A and B.

 

 

AUX-inputs are summed for monaural output via the outputs

 

 

A and B.

 

Stereo

AUX-input L is assigned to output A while AUX-input R is

 

 

assigned to output B. (this option is only available for AUX-inputs)

 

No Change

The control input parameters are not changed from the BASIC

 

 

CONFIGURATION.

Mute:

No Mute

The output signal is connected through to the masters A resp. B.

 

Mute On

Output relays switch the output signal off of masters A resp. B.

 

No Change

The control input parameters are not changed from the

 

 

BASIC CONFIGURATION.

VCA:

 

The MASTER outputs A resp. B are attenuated by the according

 

 

value in dB.

Priority Override:

Enable

MIC/LINE-input activates ducking control.

 

Disable

MIC/LINE-input does not activate ducking control.

Ducking:

Ducking Active

Ducking control is activated by the contact.

 

Auto Ducking

Ducking control is automatically activated, when the level in

 

 

MIC/LINE 1 or 2 is exceeding the Ducking Threshold (automatic

 

 

level detection function). Please note, that is a precondition

 

 

routing MIC/LINE 1 or 2 to the corresponding Master output and

 

 

setting the parameter Priority Override to Enable.

 

No Change

The control input’s parameters are not changed from the

 

 

BASIC CONFIGURATION.

8-2

Page 25
Image 25
Dynacord DRM 4000 owner manual Basic Configuration