7.4.4 Control Inputs

This offers the possibility for individually programming the parameters of the corresponding control input (contact 1 to contact 8). For details on individual parameters, please refer to chapter 8 “CONFIGURING THE DRM 4000”.

Setting each control input parameter to “No Change” is also possible. When activating a control input, all parameters that are set to “No Change” are not altered.

When the DRM 4000 is connected to your PC, using the “Online Control”-soft key allows establishing any settings in real-time.

Priority

The possibility for assigning priorities to the control input is provided here. Priority 8 represents the highest priority setting while priority 1 represents the lowest setting. The control input with the highest priority setting overrules the others whenever several control inputs are active.

The BASIC CONFIGURATION always has the lowest priority (priority 0). Therefore it is active with no control input being activated.

When assigning identical priorities to two or more control inputs, the last set overrules the others.