ACCULINK 336x E1 NTU

Troubleshooting

For problems other than those listed in the table, please

 

 

contact your service representative.

The E1 NTU is designed to provide you with many

 

years of trouble-free service. However, Table 4-7gives

 

you some direction if a problem occurs.

 

Table 4-7

(1 of 2)

Troubleshooting

Symptom

 

Possible Cause

 

Solutions

 

 

 

 

 

No power

1.

The power module is not securely attached.

1.

Check the power module attachment.

 

2.

The wall receptacle has no power.

2.

Check the wall receptacle power by plugging

 

 

 

 

in some equipment that is known to be

 

 

 

 

working.

 

 

 

Power-Up

The E1 NTU has detected an internal hardware

Contact your field service representative.

Self-Test fails

failure.

 

 

 

 

 

 

 

Message LOS on

1.

Network cable problem.

1.

Check that the network cable is securely

Loop1 or LOS on

 

 

 

attached at both ends.

Loop2 appears

2.

The far-end LTU/NTU is not transmitting.

2.

Check the far-end status.

 

 

3.

Network problem.

3.

Contact your facility provider.

 

 

 

 

 

Message LOS at

1.

G.703 DTE cable problem.

1.

Check that the G.703 DTE cable is securely

DTE appears

 

 

 

attached at both ends.

 

2.

No signal being transmitted from the DTE.

2.

Check the DTE status.

 

3.

The 120 ohm interface is being used and the

3.

Change the RX SHIELD switch to the OPEN

 

 

RX SHIELD switch is in the EARTH position.

 

position when using the 120 ohm interface.

 

 

 

 

 

Message OOF at

1.

Incompatible framing format between the

1.

Check that the framing format for the network

Net appears

 

network and the E1 NTU.

 

interface is correct.

 

2.

Network cabling problem.

2.

Check that the network cable is securely

 

 

 

 

attached at both ends.

 

3.

Facility problem.

3.

Contact your facility provider.

 

 

 

 

 

Message OOF at

1.

Incompatible framing format between the

1.

Check that the framing format for the G.703

DTE appears

 

G.703 port on the customer premises

 

DTE interface is correct.

 

 

equipment and the E1 NTU.

 

 

 

2.

G.703 DTE cabling problem.

2.

Check that the G.703 DTE cable is securely

 

 

 

 

attached at both ends.

 

 

 

 

 

Message

1.

Network cable problem.

1.

Check that your network cable is securely

RAI at Net

 

 

 

attached at both ends.

appears

2.

Far-end LTU/NTU has detected an LOS, LOF,

2.

Check the status of the far-end device.

 

 

 

AIS, or EER condition on the line.

 

 

 

3.

Facility problem.

3.

Contact your facility provider.

 

 

 

 

Message

DTE has detected an LOS, LOF, AIS, or EER

1.

Check the status of the DTE.

RAI at DTE

condition.

2.

Check that the G.703 DTE cable is securely

appears

 

 

 

 

 

attached at both ends.

 

 

 

 

 

 

 

 

 

Message

1.

Upstream LTU/NTU is transmitting an AIS.

1.

Check the status of the upstream device(s).

AIS at Net

2.

The network is transmitting an AIS.

2.

Contact your facility provider.

appears

 

 

 

 

 

 

 

 

 