Paradyne 336x E1 manual AIS at DTE, X x x x x

Models: 336x E1

1 168
Download 168 pages 21.39 Kb
Page 71
Image 71

Maintenance

Table 4-7

(2 of 2)

Troubleshooting

Symptom

Possible Cause

Solutions

Message

DTE is sending an AIS.

Check the DTE.

AIS at DTE

 

 

 

 

appears

 

 

 

 

 

 

 

Message EER at

Facility problem.

Contact your facility provider.

Net appears

 

 

 

 

 

 

 

 

 

BPV LED is ON

1.

Incompatible line coding format between the

1.

Check that the line coding format for the

 

 

DTE and the E1 NTU.

 

G.703 DTE interface is correct.

 

2.

G.703 DTE cable problem.

2.

Check that the DTE cable is securely attached

 

 

 

 

at both ends.

 

 

 

A failure message

Internal E1 NTU problem.

Record the 8-digit code, then contact your

appears followed

 

 

field service representative.

by an 8-digit code

 

 

 

 

(x x x x x x x x )

 

 

 

 

 

 

 

 

 

SNMP link is

1.

The SNMP manager configuration is

1.

Check that the configurations are matched.

down

 

mismatched with the device configuration.

 

 

 

2.

The SNMP manager's link layer protocol is not

2.

Start the link layer protocol.

 

 

running.

 

 

 

 

 

 

 

No SNMP

1.

Cable problem.

1.

Check that the cable is securely attached at

communication

 

 

 

both ends.

via the AUX port

2.

The link layer protocol is not running.

2.

Change the Aux Use configuration option to

 

 

 

 

 

None, and then back to SNMP or Daisy (as

 

 

 

 

appropriate).

 

 

 

 

 

3360-A2-GB20-20

December 1996

4-13

Page 71
Image 71
Paradyne 336x E1 manual AIS at DTE, X x x x x