Maintenance

7.When you press F1 from the E1 Registers screen, the E1 registers for the current 15-minute interval appear.

E1 Current:

Event = xx,xxx

F1 F2 F3

8.When you press F2 from the E1 Registers screen, the E1 registers for the 24-hour total interval appear.

E1 24 Hour:

VldIntvl = xx

F1 F2 F3

9.When you press F3 from the E1 Registers screen, the interval screen appears. Use this screen to choose the specific 15-minute interval.

E1 Intvl: 01

Up Down Dsply

F1 F2 F3

10.Use the and keys to position the cursor under the first or second digit in the interval number displayed, then use the F1 (Up) and

F2 (Down) keys to increment/decrement the number.

11.When you have selected the number of the interval you want to display, press F3 (Dsply) to display the registers for the interval selected. Use the scroll keys to view additional register information.

E1 Intvl: xx

ES=xxx

F1 F2 F3

You can reset the performance registers via the ClrReg command in the Control branch of the front panel menu.

To clear the performance registers,

1.From the top-level menu screen, press the key until the Ctrl selection appears on the screen.

2.Select Ctrl.

E1 HDSL NTU

Test Cnfig Ctrl

F1 F2 F3

3. From the Control screen, select ClrReg.

Control:

 

Rel

LED

ClrReg

F1

F2

F3

4.From the Clear Prf Regs screen, press F1 to clear the E1 registers.

Clear Prf Regs:

E1 HDSL DTE

F1 F2 F3

If you selected E1, the E1 performance registers are cleared. All accumulators are reset to zero and all status registers are cleared, and the current interval timer, the number of valid intervals count and the total 24-hour counts are reset to zero. The Command Complete message then appears.

3360-A2-GB20-20

December 1996

4-7