ACCULINK 336x E1 NTU

Test Jacks

Six test jacks are located on the front panel

(Figure 4-1). These test jacks allow for four break-in tests and two monitor access points to the E1 NTU.

Test jack functions are shown in Figure 4-2and described in Table 4-8.

E1 E1

LINE MON

Out Out

HDSL

E1

E1

NET

LINE

MON

Lp1

In

In

Lp2

Out

Out

 

 

495-14753

Figure 4-1. E1 NTU Test Jacks

HDSL

NET

Lp1

TERMINAL EQUIPMENT

(DTE)

LINE

INTERFACE

NTU

CIRCUITRY

LINE

HDSL

INTERFACE

NETWORK

 

 

 

 

 

 

 

 

 

E1

E1

 

 

 

 

 

HDSL

 

Port 1

Port 3

 

 

LINE

MON

 

Port 2 Port 4

NET

 

In

In

 

 

 

 

 

Lp2

495-14754

Figure 4-2. Test Jack Block Diagram

 

Table 4-8

 

Test Jack Functions

 

 

Test Jack Name

Function

 

 

HDSL NET Lp1

A break-in test jack that allows a signal to be inserted by external test equipment.

(HDSL Network Loop 1)

The signal is inserted and received on the HDSL (Loop 1) side of the E1 NTU.

 

 

HDSL NET Lp2

A break-in test jack that allows a signal to be inserted by external test equipment.

(HDSL Network Loop 2)

The signal is inserted and received on the HDSL (Loop 2) side of the E1 NTU.

 

 

E1 LINE In

A break-in test jack that allows an E1 signal to be inserted toward the E1 NTU on

 

the G.703 DTE side of the E1 NTU.

 

 

E1 LINE Out

A break-in test jack that allows an E1 signal to be inserted toward the terminal

 

equipment on the G.703 DTE side of the E1 NTU.

 

 

E1 MON In

A monitor jack that nonintrusively monitors the signal coming out of the terminal

(E1 Monitor In)

equipment on the G.703 DTE side of the E1 NTU.

 

 

E1 MON Out

A monitor jack that nonintrusively monitors the signal going into the terminal

(E1 Monitor Out)

equipment on the G.703 DTE side of the E1 NTU.

 

 

4-14

December 1996

3360-A2-GB20-20

Page 72
Image 72
Paradyne 336x E1 manual Test Jacks