ACCULINK 336x E1 NTU

Table E-1

(3 of 4)

SNMP MIB to Front Panel Command Cross-Reference

Front Panel Command

SNMP MIB Object

Test±>Lpbk±>DCLB±>Prtn

Set IfExtnsTestType for port n to testFullDuplexLoopBack

Test±>Lpbk±>Abort±>DCLB±>Prtn

Set dsx1LoopbackConfig for port n to noTest

 

 

Test±>Lpbk±>DTLB±>Prtn

Set IfExtnsTestType for port n to testLoopDTLB

Test±>Lpbk±>Abort±>DTLB±>Prtn

Set dsx1LoopbackConfig for port n to noTest

 

 

Test±>Ptrns±>Send±>QRSS±>Prtn

Set IfExtnsTestType for port n to testSendQRS

Test±>Ptrns±>Abort±>Send±>Prtn

Set IfExtnsTestType for port n to noTest

 

 

Test±>Ptrns±>Send±>32767

Set ifExtnsTestType for NET E1 to testSend32767

Test±>Ptrns±>Abort±>Send±>NET

Set ifExtnsTestType for NET E1 to noTest

 

 

Test±>Ptrns±>Send±>1in8

Set ifExtnsTestType for NET E1 to testSend1in8

Test±>Ptrns±>Abort±>Send±>NET

Set dsx1SendCode for NET E1 to dsx1SendNoCode

 

 

Test±>Ptrns±>Send±>511±>Prtn

Set IfExtnsTestType for port n to testSend511

Test±>Ptrns±>Abort±>Send±>Prtn

Set IfExtnsTestType for port n to noTest

 

 

Test±>Ptrns±>Mon±>QRSS±>Prtn

Set ifExtnsTestType for port n to testMonQRSS

Test±>Ptrns±>Abort±>Mon±>Prtn

Set ifExtnsTestType for port n to noTest

 

 

Test±>Ptrns±>Mon±>511±>Prtn

Set ifExtnsTestType for port n to testMon511

Test±>Ptrns±>Abort±>Mon±>Prtn

Set ifExtnsTestType for port n to noTest

 

 

Test±>Ptrns±>Mon±>32767±>NET

Set ifExtnsTestType for NET E1 to testMon32767

Test±>Ptrns±>Abort±>Send±>NET

Set dsx1SendCode for NET E1 to dsx1SendNoCode

 

 

Cnfig±>Load Cnfig±>Save

Set devConfigAreaCopy to desired choice(Active to Customer1, etc.)

 

 

Cnfig±>Activ±>Edit±>DTE±>DTE±>Frame

Set/Display dsx1LineType for DTE E1 to dsx1E1 or dsxE1-CRC

 

 

Cnfig±>Activ±>Edit±>DTE±>DTE±>Coding

Set/Display dsx1LineCoding for DTE E1 to dsx1HDB3 or dsx1AMI

 

 

Cnfig±>Activ±>Edit±>Port±>Prtn->Port Type

Display rs232PortType for port n to rs422, v35, or X.21

 

 

Cnfig±>Activ±>Edit±>Port±>Prtn±>TxClock

Set/Display rs232SyncPortClockSource for port n to internal or

 

external

 

 

Cnfig±>Activ±>Edit±>NET±>NET Frame

Set/Display dsx1LineType for NET E1 to dsx1E1 or dsxE1-CRC

 

 

Cnfig±>Activ±>Edit±>NET±>Mgmt Link

Set/Display dsx1Fdl for NET E1 to dsx1other or dsx1FDL-none

 

 

E-18