SNMP MIB Objects

Generic Interface Test Table ± ªifExtnsTestResultº Object (ifExtnsTestEntry 5)

This object contains the result of the most recently requested test. Only the following values are supported by the E1 NTU.

none(1) ± No test currently active.

inProgress(3) ± A test is currently in progress.

notSupported(4) ± The requested test is not supported.

unAbleToRun(5) ± The requested test cannot run due to the state of the unit.

Generic Interface Test Table ± ªifExtnsTestCodeº Object (ifExtnsTestEntry 6)

This object contains a code that contains more specific information on the test result. This object is defined as an object identifier. Only the following values are supported by the E1 NTU.

none ± No further information is available. Used for the send pattern/code and loopback tests.

inSyncNoBitErrors ± A monitor pattern (QRSS or

511)test has synchronized on the pattern and has not detected any bit errors.

inSyncWithBitErrors ± A monitor pattern (QRSS or

511)test has synchronized on the pattern and has detected bit errors.

notInSync ± A monitor pattern (QRSS or 511) test has not synchronized on the requested pattern.

Where these object identifiers are defined as follows:

wellKnownCodes ± OBJECT IDENTIFIER ::= [ifExtensions 5]

none ± OBJECT IDENTIFIER ::= [wellKnownCodes 1]

inSyncNoBitErrors ± OBJECT IDENTIFIER ::= [wellKnownCodes 2]

inSyncWithBitErrors ± OBJECT IDENTIFIER ::= [wellKnownCodes 3]

notInSync ± OBJECT IDENTIFIER ::= [wellKnownCodes 4]

Paradyne Enterprise MIB

The variable devConfigAreaCopy under the devConfigAreaCopy group in the common area of the Paradyne Enterprise MIB will be supported. This variable allows the entire contents of one configuration area to be copied into another configuration area. Only the following values are supported by the E1 NTU.

noOp(1) ± An attempt to read this value returns a ªnoOpº response.

active-to-customer1(2) ± Copy from the active area to the customer 1 area.

active-to-customer2(3) ± Copy from the active area to the customer 2 area.

customer1-to-active(4) ± Copy from the customer 1 area to the active area.

customer1-to-customer2(5) ± Copy from the customer 1 area to the customer 2 area.

customer2-to-active(6) ± Copy from the customer 2 area to the active area.

customer2-to-customer1(7) ± Copy from the customer 2 area to the customer 1 area.

factory1-to-active(8) ± Copy from the factory area to the active area. (There is only one factory area for the E1 NTU.)

factory1-to-customer1(9) ± Copy from the factory area to the customer 1 area.

factory1-to-customer2(10) ± Copy from the factory area to the customer 2 area.

3360-A2-GB20-20

December 1996

E-15