ACCULINK 336x E1 NTU

 

Table 4-2

 

(2 of 2)

 

Health and Status Messages

 

 

Message

Description

 

 

EER at DTE

An Excessive Error Rate condition has been detected on the G.703 DTE interface. The condition is

 

cleared when the error rate falls below the threshold value (10-4) for 5 seconds.

RAI at Net

A Remote Alarm Indication is being received by the network interface.

 

 

RAI at DTE

A Remote Alarm Indication is being received by the G.703 DTE interface.

 

 

MFA at Net

A Multiframe Alarm condition (2 consecutive errored multiframe alignment signals, or two

 

consecutive multiframes with all zeros in time-slot 16) has been detected on the network interface.

 

The condition is cleared when realignment (or time-slot 16 correction) occurs.

 

 

MFA at DTE

A Multiframe Alarm condition has been detected on the G.703 DTE interface. The condition is

 

cleared when realignment (or time-slot 16 correction) occurs.

 

 

RMA at Net

A Remote Multiframe Alarm signal is being received by the network interface.

 

 

RMA at DTE

A Remote Multiframe Alarm signal is being received by the G.703 DTE interface.

 

 

Primary Clk fail

The primary clock has failed. Timing for the E1 NTU is provided by the secondary clock.

 

 

Second Clk fail

The primary clock and the secondary clock have failed. Timing is provided by the internal clock.

 

 

OOF at Prtn

An Out Of Frame has been detected on data port Prtn (where n is the port number). This condition

 

only occurs if the synchronous data port's Embedded Data Link (EDL) is enabled (only available for

 

2-port and 4-port E1 NTUs).

 

 

EER at Prtn

The error rate of the received signal has exceeded the configured threshold for data port Prtn

 

(where n is the port number). This condition only occurs if the synchronous data port's Embedded

 

Data Link (EDL) is enabled (only available for 2-port and 4-port E1 NTUs). The condition is cleared

 

when the error rate falls below the synchronous data port's configured threshold value.

 

 

PORT SNMP Down

The SNMP management link is in a down state for PORT (where PORT is COM or AUX). This

 

condition occurs if the PORT is configured for SNMP, and communication between the

 

management system and the E1 NTU is not currently possible for this port. For the AUX port, this

 

condition is detected only when a device reset or power-up occurs.

 

 

Selftest failed

A failure was detected during the power-on self-test. Select STest (in the Stat branch) to display

 

more information about the failure.

 

 

DevFail xxxxxxxx

An internal error has been detected by the operating software. An 8-digit code appears for use by

 

service personnel. The condition is cleared by resetting the device.

 

 

Download failed

A download attempt was interrupted and failed to complete. The condition is cleared by resetting

 

the device.

 

 

Test in progress

A test is currently active. Select Tstat (in the Stat branch) to display more test information.

 

 

Lp1/Lp2 Reversed

The loop 1 and loop 2 connections on the HDSL network are reversed.

 

 

NTU Operational

This message only appears if the unit is configured as an NTU and there are no valid alarm or

 

status messages.

 

 

LTU Operational

This message only appears if the unit is configured as an LTU and there are no valid alarm or

 

status messages.

 

 