Paradyne 336x E1 manual Monitoring Test Patterns, Aborting Test Patterns, Patterns Mon 32767 Qrss

Models: 336x E1

1 168
Download 168 pages 21.39 Kb
Page 81
Image 81

Maintenance

Monitoring Test Patterns

Use the Monitor command to monitor 32767, QRSS, or 511 test patterns.

This command provides the number of errors detected in the test pattern (5 digits, maximum 99999).

To monitor a 32767, QRSS, or 511 test pattern,

1.From the top-level menu screen, select Test.

2.From the Test screen, select Ptrns.

Test:

Rlpbk Lpbk Ptrns

F1 F2 F3

3. From the Patterns screen, select Mon.

Patterns:

Abort Send Mon

F1 F2 F3

4.From the Patterns Mon screen, press F1 for 32767, F2 for QRSS, or F3 for 511.

Patterns: Mon 32767 QRSS 511

F1 F2 F3

If you monitor a 32767 pattern, skip Step 5.

5.From the Monitor screen, press the Function key that corresponds to the port for which you want to monitor a QRSS or 511 test pattern. Use the scroll keys, if necessary.

Monitor: Name

Prt1 Prt2 Prt3

F1 F2 F3

The Monitor screen appears with the error count. If the maximum of 99999 is exceeded, OvrFlw appears instead of the count. If the receiver loses synchronization while the monitor is active, No Sync appears.

Aborting Test Patterns

Use the Abort command to stop all test patterns or any selected test pattern active on the E1 NTU.

To abort test patterns,

1.From the top-level menu screen, select Test.

2.From the Test screen, select Ptrns.

Test:

Rlpbk Lpbk Ptrns

F1 F2 F3

3. From the Patterns screen, select Abort.

Patterns:

Abort Send Mon

F1 F2 F3

3360-A2-GB20-20

December 1996

4-23

Page 81
Image 81
Paradyne 336x E1 Monitoring Test Patterns, Aborting Test Patterns, Patterns Mon 32767 Qrss, Monitor Name Prt1 Prt2 Prt3