ACCULINK 336x E1 NTU

Configuring for Network Timing

To configure for network timing,

1.From the top-level menu screen, select Cnfig.

2.Select the configuration option set to be copied into the Edit area by using the appropriate Function key. Use the scroll keys, if necessary.

3.Select Edit.

4.From the Edit screen, press the key until the Gen selection appears on the screen.

5.Select Gen.

Edit:

NET Chan Gen

F1 F2 F3

6.Select the primary clock source. For network, press F2 (note that network is also the default).

Pri Clk Src:NET

Next NET DTE

F1 F2 F3

NOTE

The procedure for configuring the secondary clock source is similar to the example shown above. For more information on configuration options, refer to Appendix C.

Configuring for External Timing

To configure 2-port and 4-port E1 NTUs for external timing,

1.From the top-level menu screen, select Cnfig.

2.Select the configuration option set to be copied into the Edit area by using the appropriate Function key. Use the scroll keys, if necessary.

3.Select Edit.

4.From the Edit screen, press the key until the Gen selection appears on the screen.

5.Select Gen.

Edit:

NET Chan Gen

F1 F2 F3

6.Select the primary clock source. For external,

press the key until the Ext selection appears on the screen.

Pri Clk Src:NET

Next NET DTE

F1 F2 F3

7. Select Ext (external timing).

Pri Clk Src:NET

Prtn Int Ext

F1 F2 F3