ACCULINK 336x E1 NTU

Generic Interface Test Table, Generic Interface MIB

The test table provides access to additional tests (loopbacks and pattern tests) that are not in the interfaces group of MIB II.

Generic Interface Test Table ± ªifExtnsTestTypeº Object (ifExtnsTestEntry 4)

This object is a control variable used to start and stop operator-initiated tests on the interface. It provides the capability to:

Start/stop the Send 32767 test pattern on the network interface.

Start/stop the Send 1-in-8 test pattern on the network interface.

Start/stop the Send QRSS/511 test pattern on a synchronous data port.

Start sending a V.54 UP/DOWN code to the remote unit for a synchronous data port.

Start/stop the Monitor 32767 test pattern on the network interface.

Start/stop the Monitor QRSS/511 test pattern on a synchronous data port.

Start/stop the DCLB/DTLB loopback test on a synchronous data port.

The following object identifiers control tests on the interface.

noTest ± Stops the test in progress on the interface.

testFullDuplexLoopBack ± Initiates a DCLB on the interface. Only supported for the data ports.

testLoopDTLB ± Initiates a DTLB on the interface. Only supported for the data ports.

testMonQRSS ± Initiates a Monitor QRSS test on the interface. Only supported for the data ports.

testMon511 ± Initiates a Monitor 511 test on the interface. Only supported for the data ports.

testSendQRSS ± Initiates a Send QRSS test on the interface. Only supported for the data ports.

testSend511 ± Initiates a Send 511 test on the interface. Only supported for the data ports.

testSendV54Up ± Sends a V54 Up code to the remote unit. Only supported for the data ports.

testSendV54Down ± Sends a V54 Down code to the remote unit. Only supported for the data ports.

testSend32767 ± Initiates a Send 32767 test on the network interface.

testSend1in8 ± Initiates a Send 1-in-8 test on the network interface.

testMon32767 ± Initiates a Monitor 32767 test on the network interface.

Where these object identifiers are defined as follows:

noTest ± OBJECT IDENTIFIER ::= [wellKnownTests 0]

testFullDuplexLoopBack ± OBJECT IDENTIFIER ::= [wellKnownTests 1]

testLoopDTLB ± OBJECT IDENTIFIER ::= [wellKnownTests 2]

testMonQRSS ± OBJECT IDENTIFIER ::= [wellKnownTests 3]

testMon511 ± OBJECT IDENTIFIER ::= [wellKnownTests 4]

testSendQRSS ± OBJECT IDENTIFIER ::= [wellKnownTests 5]

testSend511 ± OBJECT IDENTIFIER ::= [wellKnownTests 6]

testSendV54Up ± OBJECT IDENTIFIER ::= [wellKnownTests 7]

testSendV54Down ± OBJECT IDENTIFIER ::= [wellKnownTests 8]

testSend32767 ± OBJECT IDENTIFIER ::= [wellKnownTests 11]

testSend1in8 ± OBJECT IDENTIFIER ::= [wellKnownTests 12]

testMon32767 ± OBJECT IDENTIFIER ::= [wellKnownTests 13]

E-14

December 1996

3360-A2-GB20-20

Page 143
Image 143
Paradyne 336x E1 manual Generic Interface Test Table, Generic Interface MIB