ACCULINK 336x E1 NTU

Performance Reports

Network performance is continuously monitored and maintained in network registers (NET), in G.703 DTE registers (DTE) and, if configured to do so, in far-end and near-end port registers (Prtn, where n is 1, 2, 3, or 4). Registers shown on the front panel LCD are listed in Table 4-4.

NET and DTE registers are status registers that collect performance data for the previous 24-hour period. Performance data is updated in 15-minute intervals. After 15 minutes, the current interval is rolled over into a set of accumulator registers that represent the previous 96

15-minute intervals for the register. An interval total of how many of the 96 registers contain valid data is also kept, as well as a 24-hour total for each accumulator register.

For 2-port and 4-port E1 NTUs, port performance is continuously monitored and maintained in memory registers when the port is configured to use EDL. The E1 NTU maintains two sets of port registers for each synchronous data port: far-end port registers and near-end port registers. These registers are status registers that collect performance data for the previous 8-hour period. Port data is updated in 15-minute intervals. After

15 minutes, the current interval is rolled over into a set of accumulator registers that represent the previous 32

15-minute intervals for the register. An interval total of how many of the 32 registers contain valid data is also kept, as well as a 8-hour total for each accumulator register.

NOTE

The following procedure is an example only. Screen displays may vary depending on the model and configuration of the E1 NTU. The procedure for displaying DTE and port registers is similar to this example.

To display network (NET) performance,

1. From the top-level menu screen, select Stat.

E1 HDSL NTU

Stat Test Cnfig

F1 F2 F3

2.From the Status screen, press the key until the Perf selection appears on the screen.

3.From the Status screen, select Perf.

Status:

DevHS STest Perf

F1 F2 F3

4. Select NET registers.

Performance:

NET DTE Prt1

F1 F2 F3

5.From the NET Registers screen, select E1 to view the registers that apply to the E1 (G.704) network interface. Select Lp1 or Lp2 to view the HDSL loop 1 or loop 2 network interface registers. (In the following example, E1 is selected.)

NET Registers:

E1 Lp1 Lp2

F1 F2 F3

6.From the E1 Registers screen, press F1 to view current registers (go to Step 7), press F2 to view 24-Hour Totals (go to Step 8), or press F3 to view 15-Minute Interval Registers (go to Step 9).

E1 Registers:

Cur 24Tot Intvl

F1 F2 F3

4-6

December 1996

3360-A2-GB20-20

Page 64
Image 64