Paradyne 336x E1 manual Network Interface Configuration Options

Models: 336x E1

1 168
Download 168 pages 21.39 Kb
Page 94
Image 94

Configuration Options

Network Interface

Configuration Options

Table C-3

Network Interface Configuration Options

HDSL Mode: NTU

Next NTU LTU Prev

HDSL Mode. Specifies whether the operating mode is Network Termination Unit (NTU) or Line Termination Unit (LTU). In a poll/response environment, the LTU serves as the control unit that polls the NTU and controls such items as the distribution of payload data, start-up procedures, and timing references.

NTU ± Configures for the NTU mode.

LTU ± Configures for the LTU mode.

NET Frame: noCRC

Next CRC4 noCRC Prev

Network Line Framing Format. Designates the framing format for the HDSL Network interface.

CRC4 ± Configures for the CRC4 framing format.

noCRC ± Configures for the non-CRC4 framing format.

Mgmt Link: Disab

Next Disab SNMP Prev

FDL Management Link. Specifies whether Facility Data Link (FDL) is enabled. Selecting SNMP allows SNMP management traffic to flow over the 4 kbps data link provided by FDL. Running SNMP over FDL requires an end-to-end FDL connection and cannot be terminated within the network.

Disab ± Disables the FDL Management Link.

SNMP ± Enables the FDL Management Link for SNMP.

NOTE: This configuration option is not available if EDL is enabled for SNMP.

NOTE: If the local E1 NTU's FDL is enabled for SNMP, the remote E1 NTU's FDL must also be enabled for SNMP.

HDSL: Disab

Next Disab Maint Prev

HDSL Performance Statistics. Specifies whether to monitor local HDSL performance statistics for each loop and maintain Loop 1 (Lp1) and Loop 2 (Lp2) performance registers.

Disab ± Disables Lp1 and Lp2 performance statistics.

Maint ± Maintains Lp1 and Lp2 performance statistics.

Circuit Ident:

Next Edit Clear Prev

Network Circuit Identifier. Specifies the transmission vendor's circuit identifier for the purpose of facilitating troubleshooting. The network circuit identifier is an ASCII text string that may be up to 255 characters in length.

Edit ± Allows you to edit and/or display the network circuit identifier using the generic text string entry screen.

Clear ± Allows you to clear the network circuit identifier. The network circuit identifier will be set to a null string.

3360-A2-GB20-20

December 1996

C-7

Page 94
Image 94
Paradyne 336x E1 manual Table C-3 Network Interface Configuration Options