Acculink 336x E1 Network Termination Unit
Copyright 1996 Paradyne Corporation. All rights reserved
Warranty, Sales, and Service Information
Trademarks
Operators Guide 3360-A2-GB20-20
Important Safety Instructions
Table of Contents
Glossary Index
Reference Documents
Preface
Objectives and Reader Assumptions
Related Document
Overview
Features
Introduction
Snmp Management Support
Alarm Message Capability
DTE Interface
Front Panel Emulation
Front Panel
Physical Description
Rear Panel
Model 3360 Rear Panel
AUX Port
Application Examples
Installation
Network
EDL is only available on 2-port and 4-port E1 NTUs
Snmp Connection Examples
Connection through a LAN Adapter to Snmp
Important Instructions
Optional Power Sources
Installing the +24 Vdc Power Supply
10. ±48 Vdc Single Source Power Supply Pinouts
Installing the Single ±48 Vdc Power Supply
11. ±48 Vdc Redundant Source Power Supply Pinouts
Installing the Redundant ±48 Vdc Power Supply
12. Cabling Examples
Cabling Examples
E1 Hdsl NTU
Power-Up Self-Test
Operation
E1 NTU Front Panel
Using the Front Panel
LCD
Keypad
LEDs
Test Jacks
Network Interface LEDs
System LEDs
Name Color Meaning
SIG
DTE Port LEDs
DTR
Data Port LEDs
Hdsl
Displaying Unit Identity
LED
LED Display Test NetSig1
Displaying LED Conditions
Status Perf TStat LED
Select LEDs E1 Prt1 Prt2
DTE
Changing Configuration Options
Selecting the G.703 DTE or Data Port for LED Display
LED Dsply DTE
Edit DTE Port NET
Displaying/Editing Configuration Options
Load from Activ Cust1
Choose Funct Edit Save
Port Select Copy Prt1 Prt2
Saving Edit Changes
Selecting/Copying to a Specific Port
Save Edit to Activ Cust1
Copy To All Prt1 Prt2
Configuring the E1 NTU for Snmp Management
Selecting the Port
Copy From Prt1 Prt2 Prt3
Snmp
Setting the IP Address
Com Link Next PPP Slip
Selecting the Link Layer Protocol
010.155.111.222 Up Down Save
Public Up Down Save
Specifying the Community Names and Access Types
CommunityName1 Next Edit Clear
Snmp Trap Next Enab Disab
Configuring Snmp Traps
Access Next Read R/W
Enabling Snmp Trap Messages
Num Trap Mgrs1 Next
Configuring a Destination for Snmp Traps
Selecting the Number of Trap Managers
Trapn Dst Next None Com
Configuring DS0 Channels
DTE Interface Network Interface
DTE Interface Channel Allocation
Network Interface Network Channel Allocation
Example of Channel Allocation with TS16 Available for Data
Example of Interface Worksheet with TS16 Available for Data
Port Chan Options Value Conf
10. Port Channel Configuration Worksheet Ports 1
11. Port Channel Configuration Worksheet Ports 3
Displaying DS0 Channel Assignments
Display Channel Symbols
Symbol Meaning
NET
Allocating Data Ports
Prt1
EditDTE Port
Block Channel Assignment Method
Individual Channel Assignment Method
TS16Data Data Rsvd CAS
DTE Channels TS16 Assign
Port1
Clearing DS0 Channel Allocation
Clear Channel
NET DTE
Selecting the Timing Source
12. Common Clocking Configurations
Pri Clk SrcNET Next NET DTE
Configuring for Network Timing
Configuring for External Timing
Edit NET Chan Gen
Clock Rate2048 Next 2048
Acquiring/Releasing User Interface
Acquiring the Active User Interface
Releasing the Active User Interface
Download Operations
Resetting the E1 NTU
Control ClrReg Reset
Device Reset Yes No
E1 NTU User Interface Access Security
Maintenance
Self-Test Health Messages
Self-Test Health
Status Hdsl DevHS STest
SelfTst Health Passed
Health and Status Messages
Device Health and Status
Device H/S LOS on Loop1
Port and 4-port E1 NTUs
Hdsl Loop Performance Messages
Hdsl Loop Performance
Lp1 SigQ=xx
NET Registers E1 Lp1 Lp2
Performance Reports
Status DevHS STest Perf
Performance NET DTE Prt1
E1 Hdsl DTE
VldIntvl
CurTimer
Event
Complete
StEvnt
Alarms
Snmp Trap per Interface Trap Meaning
Snmp Traps
Enterprise-Specific Trap Definitions Trap Value Event
Troubleshooting Symptom Possible Cause Solutions
Troubleshooting
X x x x x
AIS at DTE
Test Jacks
Dclbup Dclbdn
Test Commands
Remote Loopback Tests
Valid Loopback Combinations
DLB does not appear when DTE interface is disabled
Local Loopback Tests
Loopback Abort LLB PLB
Starting a Line Loopback
Starting a Payload Loopback
LLB PLB DLB
Starting a DTE Loopback
Starting a Repeater Loopback
Loopback
Loopback Dclb Prt1 Prt2 Prt3
Starting a Data Channel Loopback
PLB DLB RLB
DLB RLB Dclb
Loopback Dtlb Prt1 Prt2 Prt3
Starting a Data Terminal Loopback
Aborting Loopbacks
RLB Dclb Dtlb
LLB PLB
Test Patterns
Sending Test Patterns
Loopback Abort All
8 Network Qrss Port
Patterns Send 32767 511 1in8
Test Started
Send Name Prt1 Prt2 Prt3
Monitor Name Prt1 Prt2 Prt3
Monitoring Test Patterns
Aborting Test Patterns
Patterns Mon 32767 Qrss
Starting a Lamp Test
Lamp Test
@ABCDEFGHIJKLMNO
Displaying E1 NTU Test Status
Aborting a Lamp Test
0123456789 = ?
Test Status Messages
E1 Hdsl NTU
Front Panel Menu a
Table B-1
Technical Specifications B
Models 3360/3364/3365 NTUs Technical Specifications
Specifications Criteria
Approvals
DTE Interface Configuration Options
Configuration Options C
Table C-1 DTE Interface Configuration Options
DTE Interface Configuration Options
Net Dclb Disab Next Enab Disab Prev
Port Configuration Options
Table C-2 Port Configuration Options
Port Type E530 Next E530 V.35 RS449 X.21 Prev
InvertTxC Disab Next Enab Disab Prev
All Ones Both Next Disab DTR RTS Both Prev
Rcv RAI Halt Next None Halt Prev
Tx Clock Int Next Int Ext Prev
Near-end Disab Next Disab Maint Send Both Prev
EDL Disab Next Enab Disab Prev
Mgmt Link Disab Next Disab Snmp Prev
Far-end Disab Next Disab Maint Prev
Table C-3 Network Interface Configuration Options
Network Interface Configuration Options
Table C-4 DTE Channel Configuration Options
Channel Configuration Options
Assign By Block Next Block Chan Prev
Table C-5 Data Port Channel Configuration Options
Channel Config Dsply Clear DTE Prt1 Prt2 Prt3 Prt4
Assign To NET Next NET DTE Prtn Prtn Prtn Prev
1472 1536 1600
Port Rate Next
192 256 320 384 448 512 576 640 704 768 832 896 960 1024
1152 1216 1280 1344
N10 N11 N12 N31 Next Prev D10 D11 D12 D31
Clock Rate Next 2048 8 Prev
General Configuration Options
Table C-6 General Configuration Options
Table C-7 User Interface Configuration Options
User Interface Configuration Options
CStop Bits Next 1 1.5 2 Prev
Com Rate Next 1.2 2.4 4.8 9.6 14.4 19.2 38.4 Prev
Char Length Next 7 8 Prev
CParity None Next None Even Odd Prev
Aux Rate Next 9.6 14.4 19.2 38.4 Prev
Ignore DTR No Next Yes No Prev
Aux Use None Next None Snmp Daisy Prev
Snmp Trap Disab Next Enab Disab Prev
Alarm Configuration Options
Table C-8 Alarm Configuration Options
Alrm Msg Disab Next Enab Disab Prev
Table C-9 General Snmp Configuration Options
Snmp Configuration Options
NetMask Next Edit Clear Prev
Access 2 Read Next Read R/W Prev
CommunityName2 Next Edit Clear Prev
IP Adr Next Edit Clear Prev
Com Link PPP Next PPP Slip Prev
Com IP Adr Next Edit Clear Prev
Com NetMask Next Edit Clear Prev
Aux NetMask Next Edit Clear Prev
Aux IP Adr Next Edit Clear Prev
Gen Trap Both Next Disab Warm Auth Both Prev
Table C-10 Snmp Trap Configuration Options
Num Trap Mgrs Next 1 2 3 4 5 6 Prev
Trapn IP Adr Next Edit Clear Prev
Trap I/F All Next NET DTE E1s Ports All Prev
Entp Trap Enab Next Enab Disab Prev
Link Trap Both Next Disab Up Down Both Prev
Configuration Worksheets
Prt4 Options Value
Prt1 Options Value
Prt2 Options Value
Prt3 Options Value
Network Interface Network Channel Allocation
Port Chan Options Value Conf
Port Chan Options Value Conf
Snmp Trap Value Options
General Snmp Value Options
Hdsl Network Interface
Table D-1 Hdsl Network Connector Signal Pin Number
Pin Assignments D
DTE Interface
Table D-2 DTE Connector 120 Ohm Signal Pin Number
AUX Port Interface
Table D-3 AUX Port Connector Signal Direction Pin Number
COM Port Interface
Table D-4 COM Port Connector Signal Direction Pin Number
Figure D-2. COM Port-to-PC Cable
Direction Pin Mnemonic Number
EIA 530A Port Interface Connector
Table D-5 EIA 530A Port Interface Connector Signal Circuit
Figure D-4. EIA 530A-to-RS449 Cable
EIA 530A-to-RS449 Cable Interface
Table D-6 RS449 Cable Interface Signal Circuit
Figure D-5. EIA 530A-to-V.35 Cable
EIA 530A-to-V.35 Cable Interface
Direction Pin Number
Table D-7 Cable Interface Signal
Figure D-6. EIA 530A-to-X.21 Cable
EIA 530A-to-X.21 Cable Interface
Table D-8 Cable Interface Signal
Table D-9 DC Power Connector Signal Pin Number
Power Input Connector
Optional DC Power Cable
External Clock Interface
Table D-10 External Clock Connector Signal Pin Number
Management Information Base MIB II RFC
Snmp MIB Objects E
Interface Group, MIB
System Group, MIB
Interface Group ± ªifIndexº Object ifEntry
Interface Group ± ªifMtuº Object ifEntry
IP Group, MIB
Interface Group ± ªifLastChangeº Object ifEntry
IP Group ± ªipRouteTableº Object ip
Snmp Group, MIB
Transmission Group, MIB
Icmp Group, MIB
UDP Group, MIB
Near End Group, DS1/E1 MIB
DS1/E1 MIB RFC
Near End Group ± ªdsx1LoopbackConfigº Object dsx1ConfigEntry
DS1 Fractional Group, DS1/E1 MIB
Far End Group, DS1/E1 MIB
General Port Table, RS-232-like MIB
RS-232-like MIB RFC
Asynchronous Port Table, RS-232-like MIB
Synchronous Port Table, RS-232-like MIB
Input Signal Table, RS-232-like MIB
Output Signal Table, RS-232-like MIB
Generic-Interface Extension MIB RFC
Generic Interface Test Table, Generic Interface MIB
Paradyne Enterprise MIB
Correlation between Menu Commands and Snmp Objects
Set dsx1LoopbackConfig for DTE E1 to dsx1LineLoop
Set dsx1LoopbackConfig for NET E1 to dsx1LineLoop
Set dsx1LoopbackConfig for NET E1 to dsx1NoLoop
Set dsx1LoopbackConfig for NET E1 to dsx1PayloadLoop
External
Set dsx1LoopbackConfig for port n to noTest
Display rs232PortInSpeed or rs232PortOutSpeed for port n
Set/Display dsx1FracNumber and dsx1FracIfindex for DTE E1
IP Network Addressing
IP Network Addressing Scenario F
135.18.1.2
Front Panel Emulation G
Installing Front Panel Emulation Software
Starting Front Panel Emulation
Equipment List H
Equipment Feature Number
Activ
Glossary
BNC
CRC4
DSR
ISO
LOF
PDU
RFC RIP RJ48C RLB
TXC
Index
Index-2
Index
Index-4
Synchronous data port. See Port 1±4 interface
Index-6