Operation

Selecting the Number of Trap Managers

If you intend to issue traps to an SNMP manager(s) from this device, you must specify the number of SNMP managers that are to receive the traps.

To specify the number of SNMP managers to receive traps from this device,

1.From the top-level menu screen, select Cnfig.

2.Select the configuration option set to be copied into the Edit area by using the appropriate Function key. Use the scroll keys, if necessary.

3.Select Edit.

4.From the Edit screen, press the key until the SNMP selection appears on the screen.

5.Select SNMP.

Edit:

 

 

User

Alarm

SNMP

F1

F2

F3

6. From the SNMP Config screen, select Trap.

SNMP Config:

Gen Trap

F1 F2 F3

7.Select the number of SNMP managers to receive traps (from 1 through 6) by using the appropriate Function key. Use the scroll keys, if necessary.

Num Trap Mgrs:1

 

Next 1

2

 

F1

F2

F3

Configuring a Destination for SNMP Traps

A destination must be configured for each SNMP trap manager specified. This configuration option is displayed for the number of trap managers specified by the Number of Trap Managers configuration option.

To configure an IP address for the SNMP trap manager,

1.From the top-level menu screen, select Cnfig.

2.Select the configuration option set to be copied into the Edit area by using the appropriate Function key. Use the scroll keys, if necessary.

3.Select Edit.

4.From the Edit screen, press the key until the SNMP selection appears on the screen.

5.Select SNMP.

Edit:

 

 

User

Alarm

SNMP

F1

F2

F3

6. From the SNMP Config screen, select Trap.

SNMP Config:

Gen Trap

F1 F2 F3

7.Press F1 (Next) until the Trapn IP Address configuration option appears.