ACCULINK 336x E1 NTU

DTE Interface

Configuration Options

Table C-1

DTE Interface Configuration Options

DTE Port: Enab

Next Enab Disab Prev

G.703 DTE Port. Enables the use of the G.703 DTE port.

Enab ± Allows the use of the G.703 DTE interface.

Disab ± Prohibits the use of the G.703 DTE interface.

NOTE: When this configuration option is disabled, you cannot display or configure any other DTE Interface configuration options and TS16 is set to data. If a clock source configuration option is set to DTE, it is changed to NET.

DTE Frame: noCRC

Next CRC4 noCRC Prev

DTE Line Framing Format. Designates the framing format for the G.703 DTE interface.

CRC4 ± Configures for the CRC4 framing format.

noCRC ± Configures for the non-CRC4 framing format.

DTE Coding: HDB3

Next AMI HDB3 Prev

DTE Line Coding. Designates the line coding format to be used on the G.703 DTE interface.

AMI ± Uses the Alternate Mark Inversion coding format.

HDB3 ± Uses the High Density Bipolar 3 coding format.

Extrn DLB: Disab

Next Enab Disab Prev

DTE Loopback on External Contact. Allows the initiation and termination of a DTE Loopback (DLB) by an external contact. For more information, see the G.703 DTE Interface section in Appendix D, Pin Assignments.

Enab ± Allows the E1 NTU to begin a DLB when the external contact is closed (if the current E1 NTU state allows a DLB to be performed). If the E1 NTU is already performing a DLB, closing the contact will have no effect. Opening the contact takes the E1 NTU out of DLB. The E1 NTU remains in DLB as long as the contact remains closed.

Disab ± Prevents the state of the external contact from affecting the operation of DLB.

Send Ones: Enab

Next Enab Disab Prev

Send All Ones on DTE Failure. Specifies the action to take on the signal transmitted to the network when a valid signal cannot be recovered from the G.703 DTE interface (due to an LOS, OOF, or AIS condition).

Enab ± Sends all ones on the DS0 channels allocated to the network interface when an LOS, AIS, or OOF condition occurs on the G.703 DTE interface.

Disab ± Passes the data unchanged to the network interface channels.