Acculink 336x E1 Network Termination Unit
Operators Guide 3360-A2-GB20-20
Warranty, Sales, and Service Information
Trademarks
Copyright 1996 Paradyne Corporation. All rights reserved
Important Safety Instructions
Table of Contents
Glossary Index
Related Document
Preface
Objectives and Reader Assumptions
Reference Documents
Overview
Features
Introduction
Front Panel Emulation
Alarm Message Capability
DTE Interface
Snmp Management Support
Front Panel
Physical Description
Rear Panel
Model 3360 Rear Panel
AUX Port
Installation
Application Examples
Network
Snmp Connection Examples
EDL is only available on 2-port and 4-port E1 NTUs
Connection through a LAN Adapter to Snmp
Important Instructions
Optional Power Sources
Installing the +24 Vdc Power Supply
Installing the Single ±48 Vdc Power Supply
10. ±48 Vdc Single Source Power Supply Pinouts
Installing the Redundant ±48 Vdc Power Supply
11. ±48 Vdc Redundant Source Power Supply Pinouts
Cabling Examples
12. Cabling Examples
Power-Up Self-Test
E1 Hdsl NTU
Operation
Using the Front Panel
E1 NTU Front Panel
Keypad
LCD
Test Jacks
LEDs
Network Interface LEDs
System LEDs
Name Color Meaning
DTE Port LEDs
SIG
Data Port LEDs
DTR
Displaying Unit Identity
Hdsl
LED
Select LEDs E1 Prt1 Prt2
Displaying LED Conditions
Status Perf TStat LED
LED Display Test NetSig1
LED Dsply DTE
Changing Configuration Options
Selecting the G.703 DTE or Data Port for LED Display
DTE
Choose Funct Edit Save
Displaying/Editing Configuration Options
Load from Activ Cust1
Edit DTE Port NET
Save Edit to Activ Cust1
Saving Edit Changes
Selecting/Copying to a Specific Port
Port Select Copy Prt1 Prt2
Copy From Prt1 Prt2 Prt3
Configuring the E1 NTU for Snmp Management
Selecting the Port
Copy To All Prt1 Prt2
Setting the IP Address
Snmp
Com Link Next PPP Slip
Selecting the Link Layer Protocol
010.155.111.222 Up Down Save
Public Up Down Save
Specifying the Community Names and Access Types
CommunityName1 Next Edit Clear
Enabling Snmp Trap Messages
Configuring Snmp Traps
Access Next Read R/W
Snmp Trap Next Enab Disab
Num Trap Mgrs1 Next
Configuring a Destination for Snmp Traps
Selecting the Number of Trap Managers
Configuring DS0 Channels
Trapn Dst Next None Com
DTE Interface Network Interface
Network Interface Network Channel Allocation
DTE Interface Channel Allocation
Example of Channel Allocation with TS16 Available for Data
Example of Interface Worksheet with TS16 Available for Data
10. Port Channel Configuration Worksheet Ports 1
Port Chan Options Value Conf
11. Port Channel Configuration Worksheet Ports 3
Displaying DS0 Channel Assignments
Display Channel Symbols
Symbol Meaning
EditDTE Port
Allocating Data Ports
Prt1
NET
Block Channel Assignment Method
Individual Channel Assignment Method
DTE Channels TS16 Assign
TS16Data Data Rsvd CAS
NET DTE
Clearing DS0 Channel Allocation
Clear Channel
Port1
12. Common Clocking Configurations
Selecting the Timing Source
Edit NET Chan Gen
Configuring for Network Timing
Configuring for External Timing
Pri Clk SrcNET Next NET DTE
Releasing the Active User Interface
Acquiring/Releasing User Interface
Acquiring the Active User Interface
Clock Rate2048 Next 2048
Device Reset Yes No
Resetting the E1 NTU
Control ClrReg Reset
Download Operations
E1 NTU User Interface Access Security
Maintenance
SelfTst Health Passed
Self-Test Health
Status Hdsl DevHS STest
Self-Test Health Messages
Health and Status Messages
Device Health and Status
Device H/S LOS on Loop1
Port and 4-port E1 NTUs
Hdsl Loop Performance Messages
Hdsl Loop Performance
Lp1 SigQ=xx
Performance NET DTE Prt1
Performance Reports
Status DevHS STest Perf
NET Registers E1 Lp1 Lp2
E1 Hdsl DTE
VldIntvl
CurTimer
Event
StEvnt
Complete
Alarms
Snmp Trap per Interface Trap Meaning
Snmp Traps
Enterprise-Specific Trap Definitions Trap Value Event
Troubleshooting
Troubleshooting Symptom Possible Cause Solutions
AIS at DTE
X x x x x
Test Jacks
Dclbup Dclbdn
Test Commands
Remote Loopback Tests
Valid Loopback Combinations
DLB does not appear when DTE interface is disabled
Local Loopback Tests
Loopback Abort LLB PLB
Starting a Line Loopback
Starting a Payload Loopback
Loopback
Starting a DTE Loopback
Starting a Repeater Loopback
LLB PLB DLB
DLB RLB Dclb
Starting a Data Channel Loopback
PLB DLB RLB
Loopback Dclb Prt1 Prt2 Prt3
RLB Dclb Dtlb
Starting a Data Terminal Loopback
Aborting Loopbacks
Loopback Dtlb Prt1 Prt2 Prt3
Loopback Abort All
Test Patterns
Sending Test Patterns
LLB PLB
Send Name Prt1 Prt2 Prt3
Patterns Send 32767 511 1in8
Test Started
8 Network Qrss Port
Patterns Mon 32767 Qrss
Monitoring Test Patterns
Aborting Test Patterns
Monitor Name Prt1 Prt2 Prt3
Lamp Test
Starting a Lamp Test
0123456789 = ?
Displaying E1 NTU Test Status
Aborting a Lamp Test
@ABCDEFGHIJKLMNO
Test Status Messages
Front Panel Menu a
E1 Hdsl NTU
Specifications Criteria
Technical Specifications B
Models 3360/3364/3365 NTUs Technical Specifications
Table B-1
Approvals
Configuration Options C
DTE Interface Configuration Options
DTE Interface Configuration Options
Table C-1 DTE Interface Configuration Options
Port Type E530 Next E530 V.35 RS449 X.21 Prev
Port Configuration Options
Table C-2 Port Configuration Options
Net Dclb Disab Next Enab Disab Prev
Tx Clock Int Next Int Ext Prev
All Ones Both Next Disab DTR RTS Both Prev
Rcv RAI Halt Next None Halt Prev
InvertTxC Disab Next Enab Disab Prev
EDL Disab Next Enab Disab Prev
Near-end Disab Next Disab Maint Send Both Prev
Far-end Disab Next Disab Maint Prev
Mgmt Link Disab Next Disab Snmp Prev
Network Interface Configuration Options
Table C-3 Network Interface Configuration Options
Channel Configuration Options
Table C-4 DTE Channel Configuration Options
Assign To NET Next NET DTE Prtn Prtn Prtn Prev
Table C-5 Data Port Channel Configuration Options
Channel Config Dsply Clear DTE Prt1 Prt2 Prt3 Prt4
Assign By Block Next Block Chan Prev
1152 1216 1280 1344
Port Rate Next
192 256 320 384 448 512 576 640 704 768 832 896 960 1024
1472 1536 1600
N10 N11 N12 N31 Next Prev D10 D11 D12 D31
Clock Rate Next 2048 8 Prev
General Configuration Options
Table C-6 General Configuration Options
User Interface Configuration Options
Table C-7 User Interface Configuration Options
CParity None Next None Even Odd Prev
Com Rate Next 1.2 2.4 4.8 9.6 14.4 19.2 38.4 Prev
Char Length Next 7 8 Prev
CStop Bits Next 1 1.5 2 Prev
Aux Rate Next 9.6 14.4 19.2 38.4 Prev
Ignore DTR No Next Yes No Prev
Aux Use None Next None Snmp Daisy Prev
Alrm Msg Disab Next Enab Disab Prev
Alarm Configuration Options
Table C-8 Alarm Configuration Options
Snmp Trap Disab Next Enab Disab Prev
Snmp Configuration Options
Table C-9 General Snmp Configuration Options
IP Adr Next Edit Clear Prev
Access 2 Read Next Read R/W Prev
CommunityName2 Next Edit Clear Prev
NetMask Next Edit Clear Prev
Com Link PPP Next PPP Slip Prev
Com IP Adr Next Edit Clear Prev
Com NetMask Next Edit Clear Prev
Aux IP Adr Next Edit Clear Prev
Aux NetMask Next Edit Clear Prev
Trapn IP Adr Next Edit Clear Prev
Table C-10 Snmp Trap Configuration Options
Num Trap Mgrs Next 1 2 3 4 5 6 Prev
Gen Trap Both Next Disab Warm Auth Both Prev
Trap I/F All Next NET DTE E1s Ports All Prev
Entp Trap Enab Next Enab Disab Prev
Link Trap Both Next Disab Up Down Both Prev
Configuration Worksheets
Prt3 Options Value
Prt1 Options Value
Prt2 Options Value
Prt4 Options Value
Network Interface Network Channel Allocation
Port Chan Options Value Conf
Port Chan Options Value Conf
General Snmp Value Options
Snmp Trap Value Options
Hdsl Network Interface
Table D-1 Hdsl Network Connector Signal Pin Number
Pin Assignments D
Table D-2 DTE Connector 120 Ohm Signal Pin Number
DTE Interface
Table D-3 AUX Port Connector Signal Direction Pin Number
AUX Port Interface
Table D-4 COM Port Connector Signal Direction Pin Number
COM Port Interface
Figure D-2. COM Port-to-PC Cable
Direction Pin Mnemonic Number
EIA 530A Port Interface Connector
Table D-5 EIA 530A Port Interface Connector Signal Circuit
EIA 530A-to-RS449 Cable Interface
Figure D-4. EIA 530A-to-RS449 Cable
Table D-6 RS449 Cable Interface Signal Circuit
EIA 530A-to-V.35 Cable Interface
Figure D-5. EIA 530A-to-V.35 Cable
Table D-7 Cable Interface Signal
Direction Pin Number
EIA 530A-to-X.21 Cable Interface
Figure D-6. EIA 530A-to-X.21 Cable
Table D-8 Cable Interface Signal
Table D-9 DC Power Connector Signal Pin Number
Power Input Connector
Optional DC Power Cable
Table D-10 External Clock Connector Signal Pin Number
External Clock Interface
Snmp MIB Objects E
Management Information Base MIB II RFC
System Group, MIB
Interface Group, MIB
Interface Group ± ªifIndexº Object ifEntry
Interface Group ± ªifMtuº Object ifEntry
Interface Group ± ªifLastChangeº Object ifEntry
IP Group, MIB
IP Group ± ªipRouteTableº Object ip
UDP Group, MIB
Transmission Group, MIB
Icmp Group, MIB
Snmp Group, MIB
DS1/E1 MIB RFC
Near End Group, DS1/E1 MIB
Near End Group ± ªdsx1LoopbackConfigº Object dsx1ConfigEntry
Far End Group, DS1/E1 MIB
DS1 Fractional Group, DS1/E1 MIB
RS-232-like MIB RFC
General Port Table, RS-232-like MIB
Asynchronous Port Table, RS-232-like MIB
Generic-Interface Extension MIB RFC
Input Signal Table, RS-232-like MIB
Output Signal Table, RS-232-like MIB
Synchronous Port Table, RS-232-like MIB
Generic Interface Test Table, Generic Interface MIB
Paradyne Enterprise MIB
Correlation between Menu Commands and Snmp Objects
Set dsx1LoopbackConfig for NET E1 to dsx1PayloadLoop
Set dsx1LoopbackConfig for NET E1 to dsx1LineLoop
Set dsx1LoopbackConfig for NET E1 to dsx1NoLoop
Set dsx1LoopbackConfig for DTE E1 to dsx1LineLoop
Set dsx1LoopbackConfig for port n to noTest
External
Set/Display dsx1FracNumber and dsx1FracIfindex for DTE E1
Display rs232PortInSpeed or rs232PortOutSpeed for port n
IP Network Addressing Scenario F
IP Network Addressing
135.18.1.2
Installing Front Panel Emulation Software
Front Panel Emulation G
Starting Front Panel Emulation
Equipment Feature Number
Equipment List H
Glossary
Activ
BNC
CRC4
DSR
ISO
LOF
PDU
RFC RIP RJ48C RLB
TXC
Index
Index-2
Index
Index-4
Synchronous data port. See Port 1±4 interface
Index-6