Paradyne 336x E1 manual Starting a Data Channel Loopback, Plb Dlb Rlb, DLB RLB Dclb

Models: 336x E1

1 168
Download 168 pages 21.39 Kb
Page 77
Image 77

Maintenance

3.From the Loopback screen, press the key until the RLB selection appears on the screen.

Loopback:

Abort LLB PLB

F1 F2 F3

4. Select RLB.

Loopback:

PLB DLB RLB

F1 F2 F3

Test Started appears on Line 2. If a Repeater loopback is already in progress, the Already Active message appears. If an invalid combination of loopbacks is in progress, the error message Invld Test Combo appears (see Table4-9for valid loopback test combinations).

Starting a Data Channel Loopback

The Data Channel Loopback command (DCLB) loops the data received from the network interface, for all DS0 channels allocated to the selected port, back to the network. The loopback occurs after the data passes through the port circuitry but before it is sent out the data port. All ones are inserted into the DS0 channels allocated to that port.

DATA

AIS

 

NTU

 

 

 

 

 

 

 

 

PORTS

 

 

DCLB

 

 

HDSL

(1 - 4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA CHANNEL LOOPBACK (DCLB)

495-14775

To perform a Data Channel loopback,

1.From the top-level menu screen, select Test.

2.From the Test screen, select Lpbk.

Test:

Rlpbk Lpbk Ptrns

F1 F2 F3

3.From the Loopback screen, press the key until the DCLB selection appears on the screen.

Loopback:

Abort LLB PLB

F1 F2 F3

4. Select DCLB.

Loopback:

 

DLB

RLB

DCLB

F1

F2

F3

5.From the DCLB screen, press the Function key for the port for which you want to perform the data channel loopback. Use the scroll keys, if necessary.

Loopback: DCLB

Prt1

Prt2

Prt3

F1

F2

F3

Test Started appears on Line 2. If a Data Channel loopback is already in progress, the Already Active message appears. If an invalid combination of loopbacks is in progress, the error message Invld Test Combo appears (see Table 4-9for valid loopback test combinations).

3360-A2-GB20-20

December 1996

4-19

Page 77
Image 77
Paradyne 336x E1 manual Starting a Data Channel Loopback, Plb Dlb Rlb, DLB RLB Dclb, Loopback Dclb Prt1 Prt2 Prt3