SETUP MENU (Main Menu)

Setting the Projector Using RS-232C or Telnet

SETUP MENU (Main Menu)

 

ADVANCED SETUP MENU

SETUP MENU

---------------------------------

SETUP MENU--------------------------------

 

[1]IP Address

[2]Subnet Mask

[3]Default Gateway

[4]User Name

[5]Password

 

[6]RS-232C Baud Rate

[7]Projector Name

[8]DHCP Client

[A]Advanced Setup

 

[D]Disconnect All

[V]View All Setting

[S]Save & Quit

[Q]Quit Unchanged

setup>

 

 

 

 

 

[1]IP Address (Factory default setting : 192.168.150.2)

IP address settings. (Page 36)

ADVANCED SETUP MENU

******************** ADVANCED SETUP MENU ***********************

[1]Auto Logout Time

[2]Data Port

[5]Network Ping Test

 

[6]Accept IP Addr(1)

[7]Accept IP Addr(2) [8]Accept IP Addr(3)

[9]Accept All IP Addr

[0]Search Port

[!]Restore Default Setting [Q]Return to Main Menu

advanced>

[2]Subnet Mask (Factory default setting : 255.255.255.0)

Subnet mask settings. (Page 36)

[3]Default Gateway (Factory default setting : Not Used)

Default gateway settings. (Page 36)

[4]User Name (Factory default setting : Not Re- quired)

Setting of user name for security protection. (Page 36)

[5]Password (Factory default setting : Not Required)

Setting of password for security protection. (Page 37)

[6]RS-232C Baud Rate (Factory default setting : 9600 bps)

Baud rate settings for the RS-232C terminals. (Page

37)

[7]Projector Name

It is possible to assign a projector name. (Page 37)

[8]DHCP Client

DHCP Client settings. (Page 37)

[A]Advanced Setup

Enters ADVANCED SETUP MENU. (Page 38)

[D]Disconnect All

Disconnect all connections. (Page 38)

[V]View All Setting

Displays all setting values. (Page 34)

Can also be used with ADVANCED SETUP MENU.

[S]Save & Quit

Save set values and quit menu. (Page 35)

[Q]Quit Unchanged

Quit menu without saving setting values. (Page 35)

[1]Auto LogoutTime (Factory default setting : 5 min- utes)

Setting of time until automatic disconnection of net- work connection. (Page 38)

[2]Data Port (Factory default setting : 10002)

Setting the TCP port number used when exchang- ing data. (Page 38)

[5]Network Ping Test

It is possible to confirm that a network connection between the projector and a computer etc. is work- ing normally. (Page 39)

[6]Accept IP Addr(1) [7]Accept IP Addr(2) [8]Accept IP Addr(3)

[9]Accept All IP Addr (Factory default setting : Ac- cept All)

For improved security, it is possible to set up to three IP addresses allowing connection to the projector. Set IP addresses can be cancelled using [9] Accept All IP Addr. (Page 39)

[0] Search Port (Factory default setting : 9300)

Setting the port number used when searching for the projector. (Page 40)

[!]Restore Default Setting

Restores all setting values that can be set using the

menu to the default state. (Page 40)

[Q]Return to Main Menu

Return to the main SETUP MENU. (Page 40)

ADVANCED SETUP MENU Note

The factory default settings (“DHCP Client” is set to “OFF” on the projector) are as follows:

IP address : 192.168.150.002

Subnet mask : 255.255.255.000

Default gateway : 000.000.000.000