Eizo FlexScan L675 manual Off Timer, English, Procedure, Off timer system

Models: FlexScan L675

1 57
Download 57 pages 24.94 Kb
Page 21
Image 21
Off Timer

Off Timer

The off timer function causes the monitor to automatically enter a power off state after a predetermined amount of time has lapsed. This function was created to reduce afterimage p.46) characteristics that are particular to LCD monitors when the monitor screen is left on for a long period without use.

[Procedure]

(1)Select “Off Timer” in the ScreenManager “Others” menu.

(2)Select “Enable” and press the right and left buttons to adjust the “On Period” (1 to 23 hours).

[Off timer system]

PC

Monitor

LED

 

 

 

On Period (1H~23H)

Operation

Green

 

 

 

Last 15 min. in "On period"

Advance Notice *1

Green Flashing

 

 

 

"On period" expired

"Power Off" Mode

Flashing yellow slowly

 

 

 

*1Advance notice (LED flashing green) will be given 15 minutes before the monitor automatically enters the “Power Off” mode. To delay entering the “Power Off” mode, press the power button during the advance notice period. The monitor will continue to operate for an additional 90 minutes.

Press the power button to return to a normal screen.

The off timer function works while the PowerManager is active, but there is no advance notice before the monitor’s power is switched off.

ENGLISH

3. ScreenManager 21

Page 21
Image 21
Eizo FlexScan L675 manual Off Timer, English, Procedure, Off timer system