Design Beam 1200C™
©Elation Professional® 53 Design Beam 1200C™
located in the default position after the reset.
Gobo 1 Er
(Rotation gobo 1 error) This messa ge will appear after the reset of the fixture and if the
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the
stepping-motor is defective (or its driver circuit on the main PCB). The Rotation gobo 1 is not
located in the default position after the reset.
Gobo rotation 1 Er
(Gobo rotation 1 error) This message will appear after the reset of the fixture if the yoke’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the
stepping-motor is defective (or its driving IC on the main PCB). The Gobo rotation 1 error is
not located in the default position after the reset.
Gobo 2 Er
(Rotation gobo 2 error) This message will appear after the reset of the fixture if the yoke’s
magnetic-indexing circuit malfunction (sensor faile d or magnet missing) or the
stepping-motor is defective (or its driving IC on the main PCB). T he Rotation gobo 2 error is
not located in the default position after the reset.
Cyan Color Er
(Cyan Color-wheel error) This message will appear after the reset of the fixture if the
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the
stepping-motor is defective (o r its drive circuit on the main PCB). The Cyan Color wheel is
not located in the default position after the reset.
Magenta Color Er
(Magenta Color-wheel error) This message will appear after the reset of the fixture if the
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the
stepping-motor is defective (or its drive circuit on the main PCB). The Magenta Color-wheel
is not located in the default position after the reset.
Yellow Color Er
(Yellow Color-wheel error) This message will appear after the reset of the fixture and if the