Design Beam 1200C™
©Elation Professional® 26 Design Beam 1200C™
10.2 Information:
10.2.1.Time information
Current time
This function displays the running time of the fixture from the last power on. The
display reads “XXXX”, where “XXXX” represents the number of hours the fixture has
been running. This counter is automatically reset after every power-on.
Total Life Hours
This function tracks the fixture’s total running hours. Where “XXXX” represents the
number of hours the fixture has been powered on. This time is none destructive and
will remain in the fixtures memory indefinitely.
Last Run Hours
This function tracks a cycle run time. Use this function to keep track of rental period,
or to note the time from the last service. This setting can be reset at any time, see
“L-Timer Password.”
Lamp Hours
This function tracks the total number of lamp running hours. Where “XXXX”
represents the number of hours the lamp has been running. This counter should be
reset after every lamp change.
Lamp Off Time
This function displays the running time of the lamp from the last power on. The
display reads “XXXX”, where “XXXX” represents the number of minutes the lamp
has been running since it was last struck. This counter is automatically reset after
every power-on.
Timer Password
Use this function to enter the “Clear Last Run” password. Password is “038”
Clear Last Run
This function will allow the “Last Run Hours” function be cleared and reset.