Hi-pass

The Hi-Pass filter determines the ultimate low frequency that your sound reinforcement system is allowed to reproduce; given the capabilities of amplifiers, speakers and

transducers. Keep in mind that the DC-One signal path already includes a hi-pass filter prior to the Input PEQ DSP block. Settings to this filter in most configurations may be redundant or interactive with the initial Hi- Pass filter.

Available parameters are Frequency and Slope. The frequency parameter determines the frequency below which frequencies will be attenuated. The slope determines how quickly frequencies below that will be attenuated. (See response curve.)

Use the < Select > buttons to navigate to the filter setting you wish to adjust, and the Value Up and Down buttons to alter these settings. Press the Value Up and Down buttons once to increment values by one unit, or press and hold to scroll rapidly through available values. (Values do not wrap-around.)

Input A/B Parametric EQ

Band

Type

Frequency

Slope

Resp / Q

Gain

HIPASS

HIPASS

20Hz - 20000Hz

6dB/oct.

 

 

 

 

 

12dB/oct.

0.40 to 2.00

 

PARA EQ BAND 1-9

LOSLV

20Hz - 20000Hz

6dB/oct.

 

-15.0dB to +15.0dB

 

 

 

12dB/oct.

 

 

 

HISLV

20Hz - 20000Hz

6dB/oct.

 

-15.0dB to +15.0dB

 

 

 

12dB/oct.

 

 

 

PEQ

20Hz - 20000Hz

 

0.40 to 20

-15.0dB to +15.0dB

 

LOPASS

20Hz - 20000Hz

6dB/oct.

 

 

 

 

 

12dB/oct.

0.40 to 2.00

 

 

HIPASS

20Hz - 20000Hz

6dB/oct.

 

 

 

 

 

12dB/oct.

0.40 to 2.00

 

27

Owners Manual

Page 27
Image 27
Electro-Voice Speaker System owner manual Hi-pass, Input A/B Parametric EQ